Setup
Network Wiring
When wiring the DM network, consider the following:
NOTE:
DMNet wiring and Cresnet
®
wiring are not compatible.
•
Use Crestron Certified Wire.
•
Use Crestron power supplies for Crestron equipment.
•
Provide sufficient power to the system.
CAUTION:
Insufficient power can lead to unpredictable results or damage
to the equipment. Use the Crestron Power Calculator to help calculate how
much power is needed for the system (
).
•
For DigitalMedia CAT wiring, use DM-CBL DigitalMedia Cable. Up to
two DM Repeaters (model DM-DR, sold separately) may be required. Refer
to the latest revision of the Crestron DigitalMedia Design Guide (Doc.
4789) for complete wiring guidelines.
•
For DigitalMedia Fiber wiring, use CresFiber or other quality simplex
multimode fiber optic cable. The maximum supported cable length is 1000
feet (~300 meters). Refer to the latest version of the Crestron DigitalMedia
Design Guide (Doc. 4789) for complete wiring guidelines.
For more details, refer to “Check Network Wiring” on page 26.
The DM-TX-100/-F also uses high-speed Ethernet for communications between the
device and a control system, computer, media server and other IP-based devices. For
information on connecting Ethernet devices in a Crestron system, refer to the latest
version of the Crestron e-Control
Reference Guide (Doc. 6052), which is available
from the Crestron Web site (
).
Identity Code
NOTE:
In the SIMPL™ Windows
program, the IP ID of the DM-TX-100/-F is
assigned automatically and does not require additional programming when the
DM-TX-100/-F is dropped onto an output card of a DM switcher. Use the
information below when the DM-TX-100/-F is dropped directly into an Ethernet slot
on the control system in SIMPL Windows without a DM switcher.
The IP ID is set within the DM-TX-100/-F IP table using Crestron Toolbox. For
information on setting an IP table, refer to the Crestron Toolbox help file. The IP IDs
of multiple DM-TX-100/-F devices in the same system must be unique.
When setting the IP ID, consider the following:
•
The IP ID of each unit must match an IP ID specified in the SIMPL
Windows program.
•
Each device using IP to communicate with a control system must have a
unique IP ID.
14
•
DigitalMedia™ CAT & Fiber Transmitters 100: DM-TX-100/-F
Operations Guide – DOC. 6810C