background image

Crestron 

CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF

 infiNET™ 

Switches

 

Return and Warranty Policies 

Merchandise Returns / Repair Service 

1.  No merchandise may be returned for credit, exchange or service without prior 

authorization from CRESTRON. To obtain warranty service for CRESTRON products, 
contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may 
contact the factory and request an RMA (Return Merchandise Authorization) number. 
Enclose a note specifying the nature of the problem, name and phone number of contact 
person, RMA number and return address. 

2.  Products may be returned for credit, exchange or service with a CRESTRON Return 

Merchandise Authorization (RMA) number. Authorized returns must be shipped freight 
prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, 
with RMA number clearly marked on the outside of all cartons. Shipments arriving 
freight collect or without an RMA number shall be subject to refusal. CRESTRON 
reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus 
shipping costs on any products returned with an RMA. 

3.  Return freight charges following repair of items under warranty shall be paid by 

CRESTRON, shipping by standard ground carrier. In the event repairs are found to be 
non-warranty, return freight costs shall be paid by the purchaser. 

CRESTRON Limited Warranty 

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in 
materials and workmanship under normal use for a period of three (3) years from the date of purchase 
from CRESTRON, with the following exceptions: disk drives and any other moving or rotating 
mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; 
touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps 
are not covered. 
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON 
dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, 
if any. 
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any 
application other than that for which it was intended or if it has been subjected to misuse, accidental 
damage, modification or improper installation procedures. Furthermore, this warranty does not cover 
any product that has had the serial number altered, defaced or removed. 
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall 
CRESTRON be liable for incidental or consequential damages of any kind (property or economic 
damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any 
claim made by a third party or made by the purchaser for a third party. 
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts 
or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only 
by the unexpired portion of the warranty. 
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or 
implied, nor authorizes any other party to offer any warranty, including any implied warranties of 
merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law 
are limited to the terms of this limited warranty. This warranty statement supersedes all previous 
warranties. 

Trademark Information

 

All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered 
trademark of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft 
Corporation. 

Operations Guide - DOC. 6397A 

infiNET Switches:  Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF  

  31 

Содержание CLW-SW1/4RF

Страница 1: ...Crestron CLW SW1 4RF CLW SWS1 4RF CLW SLVS1RF infiNET Switches Operations Guide ...

Страница 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2007 Crestron Electronics Inc ...

Страница 3: ...ng Software 22 Earliest Version Software Requirements for the PC 22 Programming with D3 Pro 23 Programming with SIMPL Windows 23 Example Program 25 Uploading and Upgrading 26 Establishing Communication 26 Programs and Firmware 26 Program Checks 27 Problem Solving 28 Troubleshooting 28 Bootloader 29 Reference Documents 30 Further Inquiries 30 Future Updates 30 Return and Warranty Policies 31 Mercha...

Страница 4: ......

Страница 5: ...d interference One button and four button configurations available in white black and almond Can be ordered with custom engraved buttons Can operate as a local load control or infiNET keypad These switches can be operated with a user adjustable delay up to 10 minutes and 55 seconds For more information refer to Operation on page 10 for more information These infiNET switches are a part of Crestron...

Страница 6: ...f the infiNET Switches Installation Guide Doc 6293 which is available from the Crestron website www crestron com manuals The CLW SLVS1RF SLVS1RF is a slave unit that when used in conjunction with the SWS1RF or SWS4RF acts as an additional switch control point in a multi switch single circuit application It does not connect to an infiNET system and cannot be used without a SWS1RF or SWS4RF The SLVS...

Страница 7: ...gnetic Low Voltage Neon Cold Cathode Ceiling Fan 2 Series Control System Update File 2 3 Version 3 154 or later Load Ratings 4 Incandescent Tungsten Halogen SW1RF SW4RF 1000W SWS1RF SWS4RF 1000W SLVS1RF N A Magnetic Low Voltage 5 SW1RF SW4RF 1000VA 750W SWS1RF SWS4RF 1000VA 750W SLVS1RF N A Neon Cold Cathode 5 SW1RF SW4RF 1000VA 750W SWS1RF SWS4RF 1000VA 750W SLVS1RF N A Electronic Low Voltage SW1...

Страница 8: ... from the Crestron website 5 VA ratings are for input power to the transformer If you do not know the input power requirement of the transformer use the bulb s wattage rating to determine proper rating NOTE Crestron software and any files on the website are for Authorized Crestron dealers and Crestron Authorized Independent Programmers CAIP only New users may be required to register to obtain acce...

Страница 9: ...stable brightness via Crestron programming software four pushbuttons and a three position mode selection switch as shown in the following diagrams Each of the buttons may be pushed to perform certain functions The function of each pushbutton is determined by the position of the mode selection switch For more information refer to Operation on page 10 Parts of CLW SW4RF SWS4RF Button 2 Mode Selectio...

Страница 10: ...three position mode selection switch The brightness of the LED on the SLVS1RF is not programmable Physical View of CLW SLVS1RF Clockwise from Top Top Side and Front 1 75 in 4 45 cm 3 81 in 9 68 cm 4 13 in 10 48 cm 3 28 in 8 32 cm 1 88 in 4 77 cm 2 70 in 6 86 cm 1 50 in 3 81 cm The SW1RF SW4RF SWS1RF SWS4RF and SLVS1RF mount in a standard wallbox and are covered using a decorative faceplate not inc...

Страница 11: ...ause undesired operation Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment RF Exposure OET Bulletin 65 To comply with FCC s RF exposure limits for general population uncontrolled exposure this transmitter must be installed to provide a separation distance of at least 20 cm from all per...

Страница 12: ...b Press and hold the top or bottom of the button on the SW1RF SWS1RF or any button on the SW4RF SWS4RF c While holding the button slide the mode selection switch to the RUN position d Hold the button for approximately five seconds until the LED flashes HIGH once Immediately release the button after the LED blinks to start the switch s Acquire mode NOTE The LED can flash HIGH or LOW Refer to LED Be...

Страница 13: ...formation must be cleared from the switch s memory To clear a switch s gateway information 1 Move the mode selection switch located under the LED to the OFF position 2 Press and hold the top or bottom of the button on the SW1RF SWS1RF or any button on the SW4RF SWS4RF 3 While holding the button slide the mode selection switch to the RUN position 4 Hold the button for approximately ten seconds unti...

Страница 14: ... the load after the set delay time For information on setting a delay time refer to SET below Refer to the following table for a list of available functions when the switch is operating in the RUN mode NOTE If the behavior of the SW4RF SWS4RF has not been changed in SIMPL Windows SystemBuilder or D3 Pro the only button that will perform any function is Button 1 All of the other buttons are program...

Страница 15: ...e that was previously set will remain After setting the preset value s return the mode selection switch to the RUN position SLVS1RF The SLVS1RF has one rocker button The SLVS1RF does not have a mode selection switch It will emulate the RUN mode of the SWS1RF even if connected to a SWS4RF unless the mode selection switch of the master is set to OFF Restore Default Settings To restore the switch s d...

Страница 16: ...eight seconds In RUN mode and communicating with a gateway but the switch is not addressed in a control system program Blink OFF for second LOW for second In SET mode Blink OFF for one second HIGH for one second The switch is in the Acquire mode and searching for a gateway Blink OFF for second HIGH for second In Touch setup mode refer to Use Touch Settable ID TSID to Set MNET ID on page 13 and wai...

Страница 17: ...ange device MNET IDs for any device on the infiNET network MNET IDs can be set with the touch settable ID TSID function or manually To use TSID to set MNET IDs continue reading Use Touch Settable ID TSID to Set MNET ID below To manually change MNET IDs refer to Manually Set MNET ID in Crestron Toolbox on page 19 Use Touch Settable ID TSID to Set MNET ID Each infiNET device is shipped with the defa...

Страница 18: ...window below Network Device Tree 1 With the Network Device Tree open select Tools SMW Program Tree or click SMW Program Tree Click to Select Program 2 Click the text Click here to open program to select the SIMPL Windows program that defines the MNET IDs Select SIMPL Windows Program After selecting a file SIMPL Windows will initialize and the SMW Program Tree will be displayed 14 infiNET Switches ...

Страница 19: ...tch were created by editing each devices symbol name in the SIMPL Windows Programming Manager For information on editing a symbol name refer to the SIMPL Windows help file 3 Select Window Tile Horizontally to tile the open windows in Crestron Toolbox To simplify viewing only the SMW Program Tree and the Network Device Tree described by the SMW Program Tree should be open Network Device Tree and SM...

Страница 20: ...on Window 5 Click OK The cursor will change to a target selector 6 Click on the Network Device tree that is to be linked to the SMW Program Tree A message will be displayed indicating a successful link Link Succeeded Message 7 Right click the Lighting category in the SMW Device Tree and select Setup All Lighting Setup All Lighting The Setup Lighting window will open and display a list of unidentif...

Страница 21: ... device in the hallway followed by devices in a room Devices that do not need to be identified can be removed from the list by clicking NOTE Individual devices can be set up by right clicking the device and selecting Setup this device Follow the on screen instructions to set up the device 8 Click Start to set up the devices in the order they appear on the list The first item in the list CLW DIM1RF...

Страница 22: ... device to the duplicate MNET ID the status will be listed with the comment An error occurred changing the network ID of one or more devices Clicking No will skip the setup process for that device and continue to the next device on the list If two devices share a duplicate MNET ID the devices with the duplicate MNET IDs must be set up again NOTE If the device does not respond and or register click...

Страница 23: ...his method does not change the MNET ID as assigned in SIMPL Windows For information on setting the MNET ID in SIMPL Windows refer to Programming with SIMPL Windows on page 23 If MNET IDs have already been assigned in a SIMPL Windows program use the Touch Settable ID method described on page 13 to change the MNET ID to match the MNET ID specified in the SIMPL Windows program NOTE You may also use D...

Страница 24: ...h Newly Added infiNET Device 3 Expand the device tree until the MNET ID that is to be changed is visible Right click on the MNET ID and when the sub menu appears select Change Network ID Network Device Tree Sub Menu NOTE Any infiNET switch in the Network Device Tree can be identified using Crestron Toolbox Right click a device in the Network Device Tree and select Identify this The LED on the swit...

Страница 25: ...NET ID Repeat this procedure for each additional infiNET device requiring a MNET ID change WARNING Devices with an MNET ID of 01 or 02 cannot be used in a control system program These devices will be indicated with a icon Operations Guide DOC 6397A infiNET Switches Crestron CLW SW1 4RF SWS1 4RF SLVS1RF 21 ...

Страница 26: ...ing system as part of an overall control system project may prefer to continue using SIMPL Windows The following are the minimum recommended software versions for the PC Software TASK REQUIRED SOFTWARE VERSION Program control system to operate infiNET switches SIMPL Windows version 2 06 20 or later with SIMPL Cross Compiler version 1 1 or later and Library update 352 or later Also requires Crestro...

Страница 27: ...s and rooms at any time Programming with SIMPL Windows NOTE While SIMPL Windows can be used to program an infiNET switch it is recommended to use D3 Pro software for configuring an infiNET system SIMPL Windows is Crestron s premier software for programming Crestron control systems It is organized into two separate but equally important Managers Configuration Manager Configuration Manager is the vi...

Страница 28: ...TE The default MNET ID used by SIMPL Windows is different from the default ID that is installed on an infiNET device when it ships from the factory NOTE If the default MNET ID is already in use SIMPL Windows will assign the next available MNET ID NOTE infiNET repeaters such as the C2N MNETRPT are not added in SIMPL Windows as there is no control communication between a control system and a repeate...

Страница 29: ... program a Crestron control system by assigning signals to symbols The symbol can be viewed by double clicking on the icon or dragging it into Detail View Each signal in the symbol is described in the SIMPL Windows help file F1 Example Program An example program for infiNET switch is available from the Crestron website www crestron com exampleprograms Operations Guide DOC 6397A infiNET Switches Cr...

Страница 30: ...h communication between the PC and the control system as described in the latest version of the 2 Series Control Systems Reference Guide Doc 6256 Use the Address Book in Crestron Toolbox to create an entry for the infiNET switch using the expected communication protocol Indirect Select the MNET ID of the infiNET switch and the address book entry of the C2N MNETGW that is connected to the infiNET s...

Страница 31: ...TP site Upgrade the infiNET device s firmware via Crestron Toolbox Establish communication with the infiNET device and display the System Info window Select Functions Firmware to upgrade the infiNET device s firmware Program Checks Right click on the infiNET device to display other actions that can be performed on the infiNET device Operations Guide DOC 6397A infiNET Switches Crestron CLW SW1 4RF ...

Страница 32: ...k Acquire the device on infiNET network as described in Acquire the Switch on the infiNET Network on page 8 If the LED flashes OFF for second two times then returns to low the MNET ID of device is not set to match the MNET ID of the SIMPL Windows program Use the Network Device Tree infiNET network in Crestron Toolbox to poll the infiNET network Verify that the MNET ID for the infiNET device is set...

Страница 33: ...is low In the switch symbol of the SIMPL Windows program set the signal Enable_Local_Btn_Outputs high Refer to the SIMPL Windows help file for more information Switch does not operate as described in the manual Switch is detached from the load In the switch symbol of the SIMPL Windows program set the signal Detach_Load low Refer to the SIMPL Windows help file for more information Delay time will n...

Страница 34: ...r by model number List of Related Reference Documents DOCUMENT TITLE 2 Series Control Systems Reference Guide C2N MNETGW Operations Guide infiNET Switches Installation Guide Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling the Crestron corporate headquarters at...

Страница 35: ... days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it...

Страница 36: ...Crestron Electronics Inc Operations Guide DOC 6397A 15 Volvo Drive Rockleigh NJ 07647 2014134 Tel 888 CRESTRON 10 07 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...