Crestron
CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF
infiNET™
Switches
3. Take the C2N-MNETGW out of the
Acquire
mode once all devices have
been acquired. Refer to the latest revision of the C2N-MNETGW
Operations Guide (Doc. 6317), which is available from the Crestron
website.
To communicate with the control system program, an MNET ID value
between 03 and 20 must be assigned to the switch. For information on
assigning MNET ID values, refer to “Identity Code” on page 13.
Remove Gateway
Information from a
Switch
In some rare cases, it might be desirable to release a switch from a gateway. If a
switch is to be released from a gateway, the gateway information must be cleared
from the switch’s memory.
To clear a switch’s gateway information:
1. Move the mode selection switch (located under the LED) to the “OFF”
position.
2. Press and hold the top or bottom of the button on the -SW1RF/-SWS1RF or
any button on the -SW4RF/-SWS4RF.
3. While holding the button, slide the mode selection switch to the “RUN”
position.
4. Hold the button for approximately ten seconds until the LED flashes twice.
Immediately release the button after the LED flashes twice to clear the
switch’s gateway information. Reacquire the switch if desired.
A switch can also be released from a gateway using Toolbox. Refer to the latest
revision of the C2N-MNETGW Operations Guide (Doc. 6317) or the Crestron
Toolbox help file for instructions.
Operations Guide - DOC. 6397A
infiNET Switches: Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF
•