infiNET™ Switches
Crestron
CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF
infiNET Gateway and, if more devices are needed, more C2N-MNETGW gateways
may be added to a Cresnet
®
network.
Crestron infiNET switches operate on the 2.4 GHz “ISM band” (2400 MHz to
2483.6 MHz) at 10 mW. The output power of these devices allow RF signals to
travel approximately 150 feet indoors and 250 feet outdoors (subject to site-specific
conditions) without the use of repeaters or other infiNET devices. The range is
dependent on construction of the building, obstructions, and RF interference from
other devices. The location of the switch is an important factor in determining RF
performance. Adding more infiNET devices or repeaters to the network effectively
increases the range, strength, and reliability of the network.
The -SW1RF and -SW4RF feature a three-position mode selection switch. Refer to
“Operation” on page 10 for more information. In the absence of control system
communications, the switch can still be used to control the attached load.
The CLW-SWS1RF (-SWS1RF) and CLW-SWS4RF (-SWS4RF) are similar to the
-SW1RF and -SW4RF (respectively) with the added capability of working with one
or more slave units (CLW-SLVS1RF) in a multi-switch / single circuit application.
For more information, refer to the latest version of the infiNET Switches Installation
Guide (Doc. 6293) which is available from the Crestron website
(www.crestron.com/manuals).
The CLW-SLVS1RF (-SLVS1RF) is a slave unit that when used in conjunction with
the -SWS1RF or -SWS4RF acts as an additional switch control point in a multi-
switch / single circuit application. It does not connect to an infiNET system and
cannot be used without a -SWS1RF or -SWS4RF. The -SLVS1RF does not have a
mode selection switch. It can only be programmed when used in conjunction with a
-SWS4RF (refer to the SIMPL™ Windows
®
help file). Otherwise, it will emulate the
RUN
mode of the -SWS1RF (even if connected to a -SWS4RF) unless the mode
selection switch of the master is set to “OFF”.
These switches can be ordered with custom engraved buttons already installed by
Crestron. Engraved buttons cannot be installed or changed in the field. Contact
Crestron for more information.
These switches are available in a variety of colors and textures. The table below
shows the availability.
Available Colors/Textures
COLOR/
TEXTURE
MODEL NUMBER
SUFFIX
MATCHING FACEPLATE
(Lutron
®
Part Number Shown
White W
Not
Applicable
Smooth White
W-S
CW-1-WH
Almond A
CW-1-LA
Smooth
Almond
A-S
CW-1-LA
Black B
Not
Applicable
Smooth Black
B-S
CW-1-BL
For installation instructions, refer to the latest version of the infiNET Switches
Installation Guide (Doc. 6293), which is available from the Crestron website.