Crestron CEN-SWPOE-24 Скачать руководство пользователя страница 6

24-Port Managed PoE Switch 

  Crestron 

CEN-SWPOE-24

 

Specifications 

Specifications for the CEN-SWPOE-24 are listed in the following table. 

CEN-SWPOE-24 Specifications 

SPECIFICATION DETAILS 

Ethernet  
 Ports 

(24) 10BASE-T/100BASE-TX auto-sensing 
Fast Ethernet with PoE; 
(2) 10/100/1000BASE-T auto-sensing 
Gigabit Ethernet 

 

Network Standards 

IEEE 802.3, 802.3u, 802.3ab, 802.3af 

 Topology 

Star 

 Transmission 

Method 

Store-and-Forward 

 

Mac Addresses 

8K addresses 

 

Memory Buffer 

3 Mbits per device 

 

Switch Fabric 

8.8 Gbps non-blocking 

Power Requirements 

4.8 - 2.0 Amps @ 100-240 Volts AC,  
50/60 Hz

1, 2

 

Environmental  
 

Installation Location 

Indoor use only 

 

Temperature 

32° to 104°F (0° to 40°C)

3

 

 

Humidity 

10% to 90% RH (non-condensing) 

 

Heat Dissipation 

400 BTU/Hr 

Enclosure 

 

 Chassis 

Metal, black finish, fan cooled, vented sides 

 Faceplate 

Aluminum, black finish with polycarbonate 
label overlay 

 Mounting 

Freestanding or 2U 19-inch rack 
mountable

4, 5

 (adhesive feet and rack ears 

included) 

Dimensions  
 Height 

3.56 in (90 mm),  
3.47 in (89 mm) without feet 

 Width 

17.03 in (433 mm),  
19.00 in (483 mm) with ears 

 

Depth 

11.66 in (297 mm) 

Weight 

9.1 lbs (4.1 kg) 

1.  Consideration should be given to the connection of the equipment to the supply circuit and the effect 

that overloading of the circuits might have on over current protection and supply wiring. Appropriate 
consideration of equipment nameplate ratings should be used when addressing this concern. 

2.  Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be 

given to supply connections other than direct connections to the branch circuit (for example, use of 
power strips). 

3.  If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack 

environment may be greater than room ambient temperature. Therefore, consideration should be given 
to installing the equipment in an environment compatible with the maximum ambient temperature 
specified by the manufacturer. 

4.  Installation of the equipment in a rack should be such that the amount of air flow required for safe 

operation of the equipment is not compromised. 

5.  Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due 

to uneven mechanical loading. 

2  

  24-Port Managed PoE Switch: CEN-SWPOE-24 

Operations Guide – DOC. 7036C 

Содержание CEN-SWPOE-24

Страница 1: ...Crestron CEN SWPOE 24 24 PortManagedPoESwitch Operations Guide...

Страница 2: ...to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorien...

Страница 3: ...re Hookup 8 Configuration 10 Accessing the Configuration Utility 10 Navigating the Configuration Utility 12 Problem Solving 24 Troubleshooting 24 Reference Documents 24 Further Inquiries 24 Future Upd...

Страница 4: ......

Страница 5: ...ing of any rear port for easy monitoring and troubleshooting Customizable front panel labeling makes it easy to designate each port with a friendly descriptive name Advanced configuration is enabled t...

Страница 6: ...mm with ears Depth 11 66 in 297 mm Weight 9 1 lbs 4 1 kg 1 Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might...

Страница 7: ...controls and indicators available on the CEN SWPOE 24 CEN SWPOE 24 Physical View Front View CEN SWPOE 24 Physical View Rear View CEN SWPOE 24 Overall Dimensions Front View 3 47 in 89 mm 17 03 in 433 m...

Страница 8: ...1 Green LED indicates operating power supplied via main power input and unit is turned on 3 MGMT PORT MIRROR LED and Button 1 Recessed miniature push button and 1 green LED to enable or disable the po...

Страница 9: ...5 26 LEDs 2 Green LEDs indicate 1000 Mbps connection speed for each corresponding uplink port 9 RESET Button 1 Recessed push button to restart the device To restore the device to its factory default s...

Страница 10: ...manuals Installation Ventilation The CEN SWPOE 24 should be used in a well ventilated area The venting holes should not be obstructed under any circumstances To prevent overheating do not operate this...

Страница 11: ...e of the unit NOTE Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit for e...

Страница 12: ...so that if the unit is not rack mounted the rubber feet can provide stability when the unit is placed on a flat surface or stacked These feet should be attached prior to the hookup procedure Refer to...

Страница 13: ...for the CEN SWPOE 24 Front View MGMT Connects to Computer to Monitor Network Traffic Hardware Connections for the CEN SWPOE 24 Rear View 2 24 To POE or Non POE Network Devices GIGABIT UPLINK 25 26 To...

Страница 14: ...s of the switch defaults to 192 168 100 16 and the subnet mask defaults to 255 255 255 0 The configuration utility can be accessed from a Web browser or from the Crestron Toolbox The configuration uti...

Страница 15: ...NOTE Users can also access the Device Discovery Tool by clicking the Device Discovery Tool icon in the toolbar NOTE The security software running on the computer may send a program alert regarding the...

Страница 16: ...2 Click OK The home screen of the switch opens allowing selection of the desired functions Navigating the Configuration Utility The home menu provides six main selections Home Status General TCP IP Po...

Страница 17: ...s the version of the switch MAC address A unique address assigned to the switch System up time hr min sec Length of time the switch has been up TCP IP Settings NOTE If the TCP IP Addressing screen is...

Страница 18: ...tus selection displays system log information and the port status of all ports on the switch Refer to the sections below for more information System Log To view the system log information click the St...

Страница 19: ...ollow when setting up a new username and password NOTE The user name and password are case sensitive Current user Displays the current username of the switch Old password Enter the old password New us...

Страница 20: ...able only when UPnP is enabled In the text box enter a name for the switch to distinguish it from other devices that appear in the device list of the Device Discovery Tool The default setting is CEN S...

Страница 21: ...ox enter a text string that functions as a password to allow the SNMP manager to read configuration settings from the switch The default setting is public The read only community text string appears a...

Страница 22: ...ure the SNTP server on the switch click the General selection and then click the Time Settings subselection The Time Settings screen opens Refer to the image on the following page for more details Tim...

Страница 23: ...are Upgrade Refer to the configuration guidelines that follow In the text box enter the path to the filename containing the new firmware by clicking Browse and selecting the firmware file from the Cre...

Страница 24: ...should be saved 4 Optional In the File name text box enter a new file name if desired 5 Click Save to open the Download Complete window and save the file 6 When the download is complete click Close L...

Страница 25: ...s enabled IP will not function until a reply has been received from the server Requests will be broadcast periodically by the switch for an IP address DHCP values can include the IP address subnet mas...

Страница 26: ...n Example This screen allows editing of the current Port Setting including Speed Duplex and Flow Control the screen also displays the Link Status This screen also allows editing of the PoE setting to...

Страница 27: ...or real time analysis It can then attach a logic analyzer or RMON probe to the target port and study the traffic crossing the source port in an unobtrusive manner NOTE Monitor port speed should match...

Страница 28: ...e Documents DOCUMENT TITLE CAT5 Wiring Reference Guide Further Inquiries To locate specific information or to resolve questions after reviewing this guide contact Crestron s True Blue Support at 1 888...

Страница 29: ...s of Category 5 CAT5 unshielded twisted pair UTP cabling 100BASE TX supports high speed signaling and is relatively inexpensive Because it uses four wires for data transmission and the same packet for...

Страница 30: ...an tilt heads and power supplies are covered for a period of one 1 year touch screen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warran...

Страница 31: ...Crestron CEN SWPOE 24 24 Port Managed PoE Switch Operations Guide DOC 7036C 24 Port Managed PoE Switch CEN SWPOE 24 27 This page is intentionally left blank...

Страница 32: ...Crestron Electronics Inc Operations Guide DOC 7036C 15 Volvo Drive Rockleigh NJ 07647 2028290 Tel 888 CRESTRON 06 12 Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Отзывы: