  17 

SNMP 

Simple Network Management Protocol (SNMP) is a communication protocol 
designed specifically for managing devices on a network. SNMP is used to 
configure devices for proper operation in a network environment, as well as to 
monitor them to evaluate performance or detect potential problems. 

Traps indicating status changes are issued by the switch to specified trap managers. 
Specify trap managers so that key events are reported by this switch to the 
management station. It is possible to specify up to five management stations that will 
receive authentication failure messages and other notification messages from the 
switch. 

To configure SNMP, select either of the following from the

 

drop-down list: 

• 

Disabled:

  Prevents the switch from being administered remotely via 

SNMP. 

• 

Enabled:

  (Default setting) Allows the switch to be administered remotely 

via SNMP. 

Assign read-only or read-write privileges to the SNMP manager (applicable only if 
SNMP is enabled): 

• 

Read-only community:

  In the text box, enter a text string that functions as a 

password to allow the SNMP manager to read configuration settings from 
the switch. The default setting is public

The read-only community text 

string appears as solid black circles. 

• 

Read-write community:  

In the text box, enter a text string that functions as 

a password to allow the SNMP manager to read configuration settings from 
and write configuration settings to the switch. The default setting is private.  
The read-write community text string appears as solid black circles.

 

Add entries to the 

SNMP Trap Table

 to send notification events from the switch to 

SNMP managers when a significant event occurs: 

1.  Click the checkbox to activate trap notification.  

2. In 

the 

IP Address

 column, enter the IP address of the device to which the 

switch is to send traps. 

3. In 

the 

Community

 column, enter a read-only or read-write community text 

string. 

Syslog Remote Logging 

The Syslog sends critical logging information about the switch and connected 
devices to a remote server. To turn on this function select 

Enabled

 from the drop 

down menu and enter a server address in the 

Remote Logging Server

 field. 

Save/Cancel 

Click 

Save

 

to save the changes, the switch must be restarted for changes to take 

effect. Click 

Save and Restart

 to save changes. Click 

Cancel

 to discard changes. 

 

 

 

 

 

 

Содержание CEN-SWPOE-24

Страница 1: ...Crestron CEN SWPOE 24 24 PortManagedPoESwitch Operations Guide...

Страница 2: ...to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorien...

Страница 3: ...re Hookup 8 Configuration 10 Accessing the Configuration Utility 10 Navigating the Configuration Utility 12 Problem Solving 24 Troubleshooting 24 Reference Documents 24 Further Inquiries 24 Future Upd...

Страница 4: ......

Страница 5: ...ing of any rear port for easy monitoring and troubleshooting Customizable front panel labeling makes it easy to designate each port with a friendly descriptive name Advanced configuration is enabled t...

Страница 6: ...mm with ears Depth 11 66 in 297 mm Weight 9 1 lbs 4 1 kg 1 Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might...

Страница 7: ...controls and indicators available on the CEN SWPOE 24 CEN SWPOE 24 Physical View Front View CEN SWPOE 24 Physical View Rear View CEN SWPOE 24 Overall Dimensions Front View 3 47 in 89 mm 17 03 in 433 m...

Страница 8: ...1 Green LED indicates operating power supplied via main power input and unit is turned on 3 MGMT PORT MIRROR LED and Button 1 Recessed miniature push button and 1 green LED to enable or disable the po...

Страница 9: ...5 26 LEDs 2 Green LEDs indicate 1000 Mbps connection speed for each corresponding uplink port 9 RESET Button 1 Recessed push button to restart the device To restore the device to its factory default s...

Страница 10: ...manuals Installation Ventilation The CEN SWPOE 24 should be used in a well ventilated area The venting holes should not be obstructed under any circumstances To prevent overheating do not operate this...

Страница 11: ...e of the unit NOTE Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit for e...

Страница 12: ...so that if the unit is not rack mounted the rubber feet can provide stability when the unit is placed on a flat surface or stacked These feet should be attached prior to the hookup procedure Refer to...

Страница 13: ...for the CEN SWPOE 24 Front View MGMT Connects to Computer to Monitor Network Traffic Hardware Connections for the CEN SWPOE 24 Rear View 2 24 To POE or Non POE Network Devices GIGABIT UPLINK 25 26 To...

Страница 14: ...s of the switch defaults to 192 168 100 16 and the subnet mask defaults to 255 255 255 0 The configuration utility can be accessed from a Web browser or from the Crestron Toolbox The configuration uti...

Страница 15: ...NOTE Users can also access the Device Discovery Tool by clicking the Device Discovery Tool icon in the toolbar NOTE The security software running on the computer may send a program alert regarding the...

Страница 16: ...2 Click OK The home screen of the switch opens allowing selection of the desired functions Navigating the Configuration Utility The home menu provides six main selections Home Status General TCP IP Po...

Страница 17: ...s the version of the switch MAC address A unique address assigned to the switch System up time hr min sec Length of time the switch has been up TCP IP Settings NOTE If the TCP IP Addressing screen is...

Страница 18: ...tus selection displays system log information and the port status of all ports on the switch Refer to the sections below for more information System Log To view the system log information click the St...

Страница 19: ...ollow when setting up a new username and password NOTE The user name and password are case sensitive Current user Displays the current username of the switch Old password Enter the old password New us...

Страница 20: ...able only when UPnP is enabled In the text box enter a name for the switch to distinguish it from other devices that appear in the device list of the Device Discovery Tool The default setting is CEN S...

Страница 21: ...ox enter a text string that functions as a password to allow the SNMP manager to read configuration settings from the switch The default setting is public The read only community text string appears a...

Страница 22: ...ure the SNTP server on the switch click the General selection and then click the Time Settings subselection The Time Settings screen opens Refer to the image on the following page for more details Tim...

Страница 23: ...are Upgrade Refer to the configuration guidelines that follow In the text box enter the path to the filename containing the new firmware by clicking Browse and selecting the firmware file from the Cre...

Страница 24: ...should be saved 4 Optional In the File name text box enter a new file name if desired 5 Click Save to open the Download Complete window and save the file 6 When the download is complete click Close L...

Страница 25: ...s enabled IP will not function until a reply has been received from the server Requests will be broadcast periodically by the switch for an IP address DHCP values can include the IP address subnet mas...

Страница 26: ...n Example This screen allows editing of the current Port Setting including Speed Duplex and Flow Control the screen also displays the Link Status This screen also allows editing of the PoE setting to...

Страница 27: ...or real time analysis It can then attach a logic analyzer or RMON probe to the target port and study the traffic crossing the source port in an unobtrusive manner NOTE Monitor port speed should match...

Страница 28: ...e Documents DOCUMENT TITLE CAT5 Wiring Reference Guide Further Inquiries To locate specific information or to resolve questions after reviewing this guide contact Crestron s True Blue Support at 1 888...

Страница 29: ...s of Category 5 CAT5 unshielded twisted pair UTP cabling 100BASE TX supports high speed signaling and is relatively inexpensive Because it uses four wires for data transmission and the same packet for...

Страница 30: ...an tilt heads and power supplies are covered for a period of one 1 year touch screen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warran...

Страница 31: ...Crestron CEN SWPOE 24 24 Port Managed PoE Switch Operations Guide DOC 7036C 24 Port Managed PoE Switch CEN SWPOE 24 27 This page is intentionally left blank...

Страница 32: ...Crestron Electronics Inc Operations Guide DOC 7036C 15 Volvo Drive Rockleigh NJ 07647 2028290 Tel 888 CRESTRON 06 12 Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Отзывы: