AXES Crestron® Keypad Panels Manual – V1.1
Page 14 of 16
Analog input:
<
Temperature_F
>
The temperature value in degrees Fahrenheit multiplied by 10 to be shown on the
display.
It is visible on the screen when <
Display_Selection
> is set to 6d.
The valid values range is from 0d to 999d, that represents 0.0F...99.9F degrees.
The default value is 0d
Analog input:
<
Display_Selection
>
Selects the source of value to be shown on the display.
The values are stored in the device memory and ready to be shown any time.
The valid values range is from 0d to 6d:
0d - turn OFF the display
1d - fan speed
2d - mode selection
3d - analog value
4d - percentage value
5d - temperature Celsius
6d - temperature Fahrenheit
Out of range values are ignored.
The default value is 0d
Analog input:
<
Display_Brightness
>
The brightness of the LED/OLED screen.
The valid values range is from 10d [%] to 100d [%].
The default value is 80d
Analog input:
<
Sleep_Mode_Brightness
>
Used for decreasing the LED/OLED screen brightness when the device is in sleep mode.
The valid values range is from 0d [%] to 100d [%].
Out of range values are ignored.
The default value is 20d
Serial inputs:
<
BTN1_Active_Indicator_Color
>
...
<
BTN12_Active_Indicator_Color
>
The color in RGB HEX string format (RRGGBB) that is applied to corresponding button LED
when is ON (Active/Pressed.
The values with the wrong format are ignored
Serial inputs:
<
BTN1_Inactive_Indicator_Color
>
...
<
BTN12_Inactive_Indicator_Color
>
The color in RGB HEX string format (RRGGBB) that is applied to the corresponding button
LED when is OFF (Inactive/Released).
The values with the wrong format are ignored
Serial output:
<
RFID_Card_ID
>
If the RFID reader is available the join sends the ID of the RFID card as a string of HEX
values, f.e. A1B2C3D4FF0055AA