background image

AXES Crestron® Keypad Panels Manual – V1.1 

  

Page 3 of 16 

Safety information 

Important Information 

Read these instructions carefully before trying to install, configure, or operate products.  

The  following  special  messages  may  appear  throughout  this  bulletin  or  on  the  equipment  to  warn  of 

potential hazards or to call attention to information that clarifies or simplifies a procedure. 

 

 

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey 
all safety messages that follow this symbol to avoid possible injury or death. 

 

The  addition  of  either  symbol  to  a  “Danger”  or  “Warning”  safety  label  indicates  that  an 

electrical hazard exists which will result in personal injury if the instructions are not followed. 

 

 

 

DANGER

 

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious 

injury. 

 

 WARNING 

WARNING indicates a potentially hazardous situation which, if not avoided, can result in death or serious 

injury. 

 

 CAUTION 

CAUTION  indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  can  result  in  minor  or 

moderate injury. 

 

NOTICE 

NOTICE is used to address practices not related to physical injury. The safety alert symbol shall not be 

used with this signal word. 

Please note   

 

 

 

Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. 

No responsibility is assumed by Black Nova for any consequences arising out of the use of this material. 

 

 

 

 

 

 

A  qualified  person  is  one  who  has  skills  and  knowledge  related  to  the  construction,  installation,  and 

operation of electrical equipment and has received safety training to recognize and avoid the hazards 

involved. 

 

 

Содержание black nova AXES Series

Страница 1: ...cits straight lines simple shapes vivid colors and perfect glass surfaces are a stylish match for any interiors Its bespoke look and precise performance create an experience of pure comfort and aesthe...

Страница 2: ...Please note 3 Safety precautions 4 Introduction 5 Included in the box 6 Back End box 6 Front End box 6 Maintenance 6 Cleaning 6 Installation 7 Keypad panel front side 7 Keypad panel back side 8 Keypa...

Страница 3: ...e product described in this document is exclusively geared to specialists having qualifications in Black Nova System programming electrical specialists or persons instructed by electrical specialists...

Страница 4: ...lowed DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avo...

Страница 5: ...applications It is the duty of any such user or integrator to perform the appropriate and complete risk analysis evaluation and testing of the products with respect to the relevant specific applicatio...

Страница 6: ...e elicits straight lines simple shapes vivid colors and perfect glass surfaces are a stylish match for any interiors Its bespoke look and precise performance create an experience of pure comfort and a...

Страница 7: ...the Front End size 6 Plastite Screws quantity according to the Front End size 7 Pre installation manual available for download from Black Nova Partner Portal Please check the contents of the box immed...

Страница 8: ...ndicators Card Holder with without RFID reader DHBECRC DHBECHC RFID reader DHBEDRC Numeric Keypad DHBENK Outdoor Panel with Small Number DHBEN1 Product Preview Outdoor Panel with Small Number and Indi...

Страница 9: ...connector 2 Status LED 3 Service button 4 Cresnet communication bus 5 Temperature and Humidity Sensor Keypad panel wiring As per the Crestron standard the wiring is done according to the following dra...

Страница 10: ...wer supply must be plugged into the connector A and the WAGO 243 212 carrying the communication into the connector B as shown at side Cable for application is UTP CAT 5 Without shielding WARNING Do no...

Страница 11: ...g USB ports etc Only Back Box 1a and 1b supports the Socket Frame Use Plastite screw with Back Box type 1c Back box installation Wall cut out dimensions may vary depending on the back box manufacturer...

Страница 12: ...e 11 of 16 Keypad installation Step 1 Mount 2 on 1 using 3 Step 2 Insert 4 in 2 Single Frame 1a 1b 1c Back Box 2 Support Frame BN 3 Screws 4 AXES Keypad Double Frame 1a 1b 1c Back Box 2 Support Frame...

Страница 13: ...Active Indicator Color to the corresponding LED Low 0 Apply the Inactive Indicator Color to the corresponding LED The default value on device power up is Low 0 Digital outputs BTN1_Hold BTN12_Hold In...

Страница 14: ...f a display is available it displays the fan speed The valid values range is from 0d to 6d 0d OFF 1d Speed 1 2d Speed 2 3d Speed 3 4d Speed 4 5d Speed 5 6d AUTO speed Out of range values are ignored T...

Страница 15: ...y_Brightness The brightness of the LED OLED screen The valid values range is from 10d to 100d The default value is 80d Analog input Sleep_Mode_Brightness Used for decreasing the LED OLED screen bright...

Страница 16: ...ty of the cable Check the keypad panel configuration Crestron SIMPL application Check that keypad panel has the proper ID configured Check that keypad panel received configuration from the network Che...

Страница 17: ...ge caused by service including the installation of updates or extensions or repairs performed by anyone who is not authorized Damage caused by connecting devices to the products of other manufacturers...