Configure AV2 and PRO2 (Continued)
DEVICE
SYMBOL
DROP
ADDITIONAL
LIBRARY REQUIRED
WHERE
SETUP
Serial
Drivers
(General)
Desired IR
devices
(drivers are
arranged by
manufacturer
or device)
C2I-IR8
(Slot 5)
As devices are dropped onto slot 5, they
are assigned to port A through port H, in
sequence by default. If more than eight
devices are to be controlled via this port,
the assignment sequence repeats.
REASSIGN DEVICES TO A PORT
(OPTIONAL) - Double-click on the device
that needs to be reassigned to open the
"Device Settings" window. Select the
PORT ASSIGNMENT tab and scroll to
the desired port address.
(Alternatively, single-click then right
mouse-click on device that needs to be
reassigned. Select Configure to open
"Device Settings" window.)
- or -
C2IR One-
way serial
driver
As devices are dropped onto slot 5, they
are assigned to port A through port H, in
sequence by default. If more than 8
drivers are needed in the system, the
sequence is repeated again, as needed.
COMMUNICATION PARAMETERS - In
the System Tree, scroll down to Slot 5:
C2I-IR8 within the control system and
expand to display the individual ports.
Single-click on the desired port, then
right-mouse click and select Configure.
Select the SERIAL SETTINGS tab to
display a window that allows for the
assignment of communication
parameters.
REASSIGN DEVICES TO A PORT
(OPTIONAL) - In the System Tree,
double-click on the device that needs to
be reassigned to open the "Device
Settings" window. Select the PORT
ASSIGNMENT tab and scroll to the
desired port address.
(Alternatively, single-click then right
mouse-click on device that needs to be
reassigned. Select Configure to open
"Device Settings" window.)
Not
applicable
(N/A)
Built-in digital
I/O port
(Slot 6)
N/A
None required.
Not
applicable
(N/A)
Built-in relay
output port
(Slot 7)
N/A
None required.