![Crest Audio FORWARD TECHNOLOGY F-100 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/crest-audio/forward-technology-f-100/forward-technology-f-100_operation-and-maintenance-manual_2683159008.webp)
Forward Technology – a Crest Group Company
Operation and Maintenance Manual for F-100 Cleaning System
F-100 Manual Rev H
Non-Flammable
7
SYSTEM SHUTDOWNS
NORMAL SHUTDOWN: Solvent Remains In Machine
•
When the cleaning cycle is complete
and
•
All baskets have been removed from the machine,
then
•
Press the
MAIN SCREEN
button to return to the Main Menu. Press the
COOLDOWN
button to remove the machine from automatic and remove heat from the solvent and
allowing it to cool.
NOTE: The cooling system will remain active to minimize solvent loss.
TOTAL SHUTDOWN: Solvent Is To Be Removed From Machine
•
When the cleaning cycle is complete
and
•
All baskets have been removed from the machine,
then
•
Press the
MAIN SCREEN
button in the upper right corner of the screen to return to the
Main Menu. Press the
COOLDOWN
button to remove the machine from automatic and
start the cool down of the solvent.
1. It is recommended that the solvent be allowed to cool to room temperature before
attempting to drain the solvent from the machine. Heated solvents are more volatile
and this increases the risks associated with handling the solvent significantly.
2. Use the Fill/Drain procedure to drain the solvent.
3. Press the
CONTROL POWER OFF
button on the main cabinet.
Figure 4: Control Power Off/ Emergency Stop Buttons