Stagehand Mini
2
Manual
Page 11
Installation
The Stagehand Mini
2
has been designed primarily for mounting in a standard 19” equipment rack. It occupies a
3U space measuring 5.25” vertically. For easy operation, it is most convenient to mount the Mini
2
horizontally,
you can also safely mount it vertically.
Figure 6
Rack
Mount
For touring applications, or permanent installations the Stagehand can be rack mounted in a standard 19”
equipment rack using the included mounting ears. However, the rack must be orientated horizontally so that
the Stagehand remains vertical in the rack for proper heat ventilation.
Electrical
Connections
Once the Mini
2
is installed in your rack it’s time to take a look at the back side of the case and figure out all the
electrical connections.
Power
Input
Connection
The power inlet is a standard IEC C14 cord like many consumer electronics (computers, projectors, TV’s, etc).
The power inlet has a small fuse compartment next to the cord that slides out for easy replacement.
Figure 7
Included with your Stagehand Mini
2
is a 6’ power cord with a locking IEC connector on one end and an Edison
plug on the other. The locking connector presses onto the power inlet and automatically locks into position to