Reverse Limit – a Normally Closed (N.C.) switch can be wired to this pair of terminals. If the switch is
activated, the Stagehand will not allow further motion in the reverse direction until the limit is cleared
either by adjusting the switch mechanically or by moving in the forward direction far enough to clear the
limit switch.
Forward Limit – a Normally Closed (N.C.) switch can be wired to this pair of terminals. If the switch is
activated, the Stagehand will not allow further motion in the forward direction until the limit is cleared
either by adjusting the switch mechanically or by moving in the reverse direction far enough to clear the
limit switch.
Since the Stagehand provides three (3) separate pins that all source 12vdc, one for each limit signal, you can
reduce the wiring in your machine to four (4) wires by using just one of the 12vdc source pins and three (3)
wires for the three limit return signals. Sometimes it is more convenient to wire a pair of conductors for
each switch, other times it may be better to reduce the number of conductors by sharing a common voltage
source. Both options are shown below: