16
WeedRoller PRO Owner's/Parts Manual
54678-00 R010114
Section
4.2 OFF-SEASON STORAGE
•
The WeedRoller PRO can be left in the lake year round if the lake does not freeze over. Remove the WeedRoller
PRO and store it over the winter if the lake freezes over.
•
If you have a roll-away dock, the complete Weed Roller unit can be stored with it. Raise the dock to lift the drive
head assembly off the ground and fasten each roller assembly to the dock for easy storage. Cover the control
top with a plastic bag or cover to protect it from outdoor conditions. Be sure to completely drain water from
rollers before storage.
•
The unit can be disassembled into four separate sections: the drive head assembly and three individual rollers.
Be sure to drain water from rollers before storing.
Be sure to drain the water from the rollers before stor-
age if freezing is possible.
NOTE
4.1 TRIPPED CIRCUIT BREAKER
SERVICE & MAINTENANCE
4
The power converter has an 8 amp circuit breaker on the 28 volt AC side.
1. Disconnect the power converter from the 110 volt supply and inspect before resetting the breaker.
2. Clear weeds and/or obstructions from the rollers or arc before restarting.
Blowing a fuse or tripping the circuit breaker is a warn-
ing that you have overloaded the circuit. Determine
the cause and correct it.
NOTE
4.3 GEARBOX MAINTENANCE
Crary Industries recommends that the fluid in the lower gear case should be changed annually prior to storage. This will
ensure that if water has entered the gearbox, it will be removed prior to storage, preventing damage to the gear case
by freezing.
The use of LUBRIPLATE Pure Flush prior to each oil change of the gearbox will help to thin the grease and remove
sludge within the gear case that may have built up over time. When changing the gearbox fluid, use the following steps:
1. With the rollers removed and the power of the unit disconnected, lay the WeedRoller unit on its side with the gearbox
positioned over an oil pan. Remove the plugs on each side of the gear case and allow as much of the oil as possible
to drain out.
2. Reinstall the plug on the bottom side of the gear case and fill the gearbox with LUBRIPLATE Pure Flush
(PN 30338-00). Then reinstall the plug on the top side of the gear case and stand the unit up in operating position.
3. Reconnect the power and start the WeedRoller unit. Allow it to run until it has a Cycle Timeout Fault which is
indicated by both the Left & Right Park Position lights flashing green simultaneously. This will shut the unit down
after approximately 2 hrs 15 mins. Press and hold the Reverse/Reset button for 3 seconds to clear the fault.