5
MODEL
NO
HP
VOLT
PH/Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
CORD
SIZE
CODE
TYPE
CORD
O.D.
± .02 (.5)
in (mm)
WINDING
RESISTANCE
MAIN -- START
SGV2002L
2
200
1 / 60
3450
F
17.0
53.0
12/4
SOW
.67 (17)
0.9 -- 7.2
SGV2022L
2
240
1 / 60
3450
F
16.0
46.0
12/4
SOW
.67 (17)
1.5 -- 5.1
SGV2062L
2
200
3 / 60
3450
J
11.0
42.0
12/4
SOW
.67 (17)
2.4
SGV2032L
2
240
3 / 60
3450
H
9.0
36.0
12/4
SOW
.67 (17)
3.1
SGV2042L
2
480
3 / 60
3450
H
4.0
18.0
12/4
SOW
.67 (17)
12.4
SGV2052L
2
600
3 / 60
3450
H
3.2
14.4
12/4
SOW
.67 (17)
16.1
Winding Resistance ± 5%, measured from terminal block. Pump rated for operation at ± 10% voltage at motor.
Optional
- Temperature sensor cable for all models is 14/3 SOW, 0.55 ± .02 O.D. (Not used on SGV2022L).
Optional
- Moisture and Temperature sensor cable for all models is 18/5 SOW, 0.49 ± .02 O.D., replaces Temperature sensor cable.
Recommended Breaker & Heater Sizes
Pump Model
HP Phase
Volts
Breaker Size Heater Size Voltage Relay Start Capacitor
Run Capacitor
SGV2002L
2
1
200
30 AMP
K-60
MARS 68
143 mfd - 220 volts
20 mfd - 370 volts
SGV2022L
2
1
240
30 AMP
K-57
MARS 68
143 mfd - 220 volts
45 mfd - 450 volts
SGV2062L
2
3
200
20 AMP
K-53
N/R
N/R
N/R
SGV2032L
2
3
240
20 AMP
K-50
N/R
N/R
N/R
SGV2042L
2
3
480
15 AMP
K-33
N/R
N/R
N/R
SGV2052L
2
3
600
15 AMP
K-31
N/R
N/R
N/R
NOTE: Factory recommended heater sizes may vary depending on pump station requirements.