Models PC13316V-01
and P13316V-01
Pedestal Sump Pump
INSTALLATION, OPERATION, & PARTS MANUAL
SAFETY INFORMATION
Carefully read and follow all safety instructions in this
manual or on pump.
This is the safety alert symbol.
When you see this
symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for
personal injury!
warns about hazards that
will
cause serious
personal injury, death or major property damage if ignored.
warns about hazards that
can
cause serious
personal injury, death or major property damage if ignored.
warns about hazards that
will
or
can
cause
minor personal injury or property damage if ignored.
The word
NOTICE
indicates special instructions which are
important but not related to hazards.
DESCRIPTION
This Pedestal Sump Pump is designed for home sumps.
Unit is equipped with a 3-prong grounding-type power cord.
Sleeve bearings on motor shaft never need lubrication.
Motor has automatic reset thermal protection.
SPECIFICATIONS
Power supply required . . . . . . . . . . . . . . . . . . . . .115V, 60 HZ
Motor duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intermittent
Liquid Temp. Range . . . . . . . . . . . . . . .32° F-70° F (0°-21° C)
Individual Branch Circuit Required . . . . . . . . . . . . . .15 Amps
Discharge Adapter . . . . . . . . . . . . . . . . . . . . . . . . .1-1/4" NPT
GENERAL SAFETY INFORMATION
Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained,
and used. However, unusual circumstances (interruption of
power to the pump, dirt/debris in the sump, flooding that
exceeds the pump’s capacity, electrical or mechanical failure
in the pump, etc.) may prevent your pump from functioning
normally. To prevent possible water damage due to flooding,
consult your dealer about installing a secondary sump
pump, a DC backup sump pump, and/or a high water alarm.
See the “Troubleshooting Chart” in this manual for informa-
tion about common sump pump problems and remedies. For
more information, see your dealer or call customer service
at 1-888-782-7483.
© 2005
S499 (Rev. 2/11/09)
293 Wright Street • Delavan, WI 53115
GPM (LPM) AT TOTAL FEET (m)
5
10
15
20
Model
(1.5m)
(3m)
(4.6m)
(6.1m)
CAPACITY GALLONS(L)/MINUTE
PC13316V-01
50
40
27
12
P13316V-01
(189) (151)
(102)
(45)
Individual
*Switch
Motor
Branch
Setting
Motor
Full Load
Circuit
in inches (mm)
HP
Amps
Req. (Amps)
On
Off
10-12"
2-1/2"
1/3
3.5
15
(254-305)
(964)
No flow at 22 feet of lift.
PERFORMANCE
MOTOR, SWITCH & CORD
SPECIFICATIONS