28
NOTE: Repeat all electrical checks & pressure tests prior to replacing oil.
Replacing Oil
Motor housing - Set unit upright and refi ll with (see chart for type and amount) new cooling oil. Fill
to 1” above motor as an air space must remain in the top of the motor housing to compensate for oil
expansion. Apply pipe thread compound to threads of pipe plug and assemble to motor housing.
NOTE:
Reference oil chart for suitable replacement oils.
SUPPLIER
GRADE
BP
Enerpar SE100
Conoco
Pale Paraffi n 22
Mobile
D.T.E. Oil Light
G & G Oil
Circulating 22
Imperial Oil
Voltesso-35
Shell Canada
Transformer-10
Texaco
Diala0 Oil-AX
Seal Chamber
Set unit on its side with plug opening upward and fi ll completely with (see chart for type and amount) new
oil. Apply pipe thread compound to threads of pipe plug and assemble to intermediate coupling.
Содержание Barnes SGV 2 HP
Страница 18: ...18 Inner Seal From intermediate coupling press out stationary seal with a flat screwdriver 34 ...
Страница 23: ...23 Pin Placement Diagram Figure Figure B B ...
Страница 29: ...29 SGV 2HP Exploded View Figure Figure C C ...
Страница 31: ...31 Notes ...
Страница 32: ...CRANE PUMPS SYSTEMS INC 420 THIRD STREET PIQUA OHIO 45356 U S A ...