22
Motor Housing
Lubricate and set square ring into bore on intermediate coupling.
Install ground wire in end bell if removed (Use proper bolt to secure ground lug). Place fi berglass sleeve
over motor and ground leads if removed. Pull wires through opening in top of motor housing while
lowering motor housing onto intermediate coupling. Connect wires to pins on the bottom of the terminal
block.
NOTE:
Wiring Digram on next
page.
Lubricate o-ring and slide
terminal block back into housing.
Make sure terminal block is
engaged and install snap ring
to retain terminal block. Tighten
bolts and lock washers into
motor housing.
43
42
44
45
46
47
Содержание Barnes SGV 2 HP
Страница 18: ...18 Inner Seal From intermediate coupling press out stationary seal with a flat screwdriver 34 ...
Страница 23: ...23 Pin Placement Diagram Figure Figure B B ...
Страница 29: ...29 SGV 2HP Exploded View Figure Figure C C ...
Страница 31: ...31 Notes ...
Страница 32: ...CRANE PUMPS SYSTEMS INC 420 THIRD STREET PIQUA OHIO 45356 U S A ...