[1] Module Input: Connects balanced XLR analogue
inputs into each 500 series slot. Input sensitivity varies
depending on the type of module inserted.
[8] USB 2.0: Used for software updating and
non-audio purposes only. Cannot be used as an
audio interface.
[2] Insert: Connects external equipment in-line after
the 500 series module but before the A/D of each 500
series slot. Utilises a standard Y-split or insert cable.
(Tip=send, Ring=return).
[9] Grounding Post: Enables direct binding to
chassis ground to help eliminate ground loops in
specific setups.
[3] Module Direct Outputs: Sends balanced, line-level
outputs of each 500 series slot for connection to
external converters and equipment. Module Direct
Outputs are positioned post-insert point, pre Mix
Level.
[10] Aux Input: Connects analogue playback
sources from external audio interfaces directly
into 500ADAT’s monitoring paths.
[4] C.A.S.T. A, B, C, & D Inputs: Enables I/O relocation
and expansion via Cranborne Audio C.A.S.T. enabled
breakout boxes.
[11] Power: Provides 500ADAT with power via the
provided external 24v 5A DC power supply. No
other power supply should be used.
[5] ADAT I/O: Interfaces 500ADAT’s 8-in/8-out ADAT
optical lightpipe channels directly into your audio
interface of choice.
[12] C.A.S.T. Link: Enables linking of the Summing
Mixers between 500ADAT and a 500R8. C.A.S.T.
link transmits the Summing Mixer into the
connected 500R8 for monitoring.
[6] Word Clock I/O: Enables sending and/or receiving
word clock information to/from external digital
devices.
[13+14] Aux 1 & 2 Outputs: Connects balanced line
outputs of 500ADAT’s Aux 1 and 2 Busses to
external monitoring devices or similar via 1/4”
jacks.
[10] Clock Settings: Adjusts 500ADAT’s Clock Settings
including Clock Source and Sample Rate
.
[15] Mix Output: Connects line outputs of
500ADAT’s built-in Summing Mixer directly to
external converters or similar via 1/4” jacks.
500ADAT User Manual
-Page 7-
©201
9
Cranborne Audio Ltd