TEST FUNCTIONS
The test function is useful to verify and diagnose the operation of the control unit
and the connection of the wiring during installation, even with the motor
disconnected. After having powered the control unit, having implemented the
learning process of the remote control and accessed the test function, you can
check the operation by selecting the button (or selector) that opens or closes the
cover; if the red LED inside the cover is on, the control unit and all the wiring is
working correctly.
For the control unit to be made active and operative, it is MANDATORY to switch
off and on by pressing the (red) mushroom-shaped emergency button.
The procedure to perform this kind of test is:
1. Press the (red) mushroom-shaped emergency button to switch the device off and wait at
least 1 second
2. Release the (red) mushroom-shaped emergency button to switch the device on again
3. Within 3 seconds after start-up, press buttons A and D on the remote control
simultaneously until the LED will light up for about 100 ms (wait for about 3 s). This
means that the control unit has is entered the learning mode.
4. Release buttons A and D on the remote control and wait at least 1 second; within 10
seconds, in the control unit learning mode, activate the test function.
5. Activate the test function as follows: press and hold the D button on the remote control
until the LED will be activated with two consecutive pulses of about 100 ms to indicate
that the control unit has successfully performed the function and exited the learning
mode
6. Select the cover opening or closing button (or selector) to verify operation. If the red
LED inside the cover is on, the control unit is running.
7. Switch the control unit off and on to make it active and operative by pressing the
(red) mushroom-shaped emergency button.
In the learning mode, the control unit can only perform one function at a time. The test
function cannot be enabled unless the remote control code is first saved.
Once you enter the learning mode, the control unit, will wait 10 seconds for a function to be
executed (learning-test-deletion). If no action is launched, once the 10 seconds elapse, the
LED will be activated with two consecutive pulses of about 100 ms and the control unit
will automatically exit the learning mode. When the control unit exits the learning mode, it
is automatically operational
.