Authorized Technician Maintenance, cont.
Problem
Motor will not operate.
Solution
1. Check main breaker.
2. Check fused disconnect.
3. Check motor starter thermal overloads. Reset if necessary.
4. Check motor starter coil.
5. Check magnetic door switch (if applicable).
Motor runs but ram does not move.
1. Check for proper motor rotation. (clockwise from the fan end).
2. Check hydraulic fluid level.
3. Check hydraulic hose connections from power unit to compactor.
4. Check the directional valve for proper operation.
5. Check relief valve for proper adjustment.
6. Check the limit switch.
Note: Before performing any maintenance, always
LOCK AND TAG-OUT THE DISCONNECT.
Compactor shifts erratically.
Compactor makes excessive noise.
1. Check for proper system pressure.
2. Check for proper pressure switch adjustment.
3. Check directional valve.
1. Check hydraulic fluid level.
2. Check ram guide for lubrication.
3. Check for water or air in hydraulic fluid.
4. Check oil filter and suction line components for tightness.
TROUBLE-SHOOTING CHART
Содержание SCR-02
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 8: ...8 ...
Страница 9: ...9 Operation Section ...
Страница 10: ...10 SAFETY DECALS ...
Страница 11: ...11 SAFETY DECAL PLACEMENT ...
Страница 19: ...19 Authorized Technician Maintenance Section ...
Страница 24: ...24 Authorized Technician Maintenance cont Electrical Schematic ...
Страница 25: ...25 Authorized Technician Maintenance cont Hydraulic Schematic ...
Страница 26: ...26 Authorized Technician Maintenance cont Hydraulic Schematic ...
Страница 28: ...28 Parts Section ...
Страница 29: ...29 SAFETY DECAL PLACEMENT ...
Страница 30: ...30 Installation Section ...
Страница 33: ...33 Hauler Section ...
Страница 35: ...35 Warranty Policy And Procedure Section ...