background image

10. Testing Your Fan.

It is recommended that you test fan before 
finalizing installation. Restore power from circuit 
box and light switch (if applicable). Test fan speeds 
with the pull chain on switch housing. Start at the 
OFF position (no blade movement). First pull will 
set the fan to HI. Second pull will set the fan to 
MEDIUM. Third pull will set the fan to LOW. Fourth 
pull will again set the fan to OFF setting. Test light 
with pull chain in the middle. (

diagram 1

) If fan 

and/or light do/does not function, please refer to 
"Troubleshooting" section to solve any issues 
before contacting Customer Service.

Turn fan completely off 

before 

moving the reverse 

switch. Set reverse switch to recirculate air 
depending on the season:
 

- DOWN position in summer (

diagram 2

)

 

- UP position in winter (

diagram 3

)

A ceiling fan will allow you to raise your 
thermostat setting in summer and lower your 
thermostat setting in winter without feeling a 
difference in your comfort.

Important:

 Reverse switch must be set either 

completely UP

 or 

completely DOWN

 for fan to 

function. If the reverse switch is set in the 

middle

 

position (

diagram 4

), fan will not operate.

Attach pull chain extensions supplied or custom 
pull chain extensions (sold separately) to ends of 
the pull chains.

page 8

diagram 2

diagram 3

diagram 4

diagram 1

light pull chain
extension

fan pull

chain extension

motor housing

reverse
switch

Содержание WC42BNK5C1

Страница 1: ...pg 4 Fan Assembly pg 5 Motor Housing Assembly pg 5 Blade Assembly pg 6 Light Kit Assembly pgs 6 7 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 net weight of fan 11...

Страница 2: ...fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5...

Страница 3: ...have been included 2 Parts Inventory a hanging bracket 1 piece b motor housing 1 piece c motor assembly 1 piece d blade arm 5 pieces e blade 5 pieces f light kit fitter 1 piece g glass shade 1 piece...

Страница 4: ...an is suitable for room sizes up to 144 square feet 13 4 square meters Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position...

Страница 5: ...cal Code If you are unfamiliar with electrical wiring or if the house building wires are different colors than those referred to below please use a qualified electrician When fan is secured in place o...

Страница 6: ...rs j hook 7 Motor Housing Assembly Temporarily raise motor housing to hanging bracket to determine which 2 screws in hanging bracket align with slotted holes on top rim of motor housing Lower motor ho...

Страница 7: ...th motor screw holes and attach blade arm with lock washers and blade arm screws Before securing screws permanently repeat this procedure with remaining blade arms Secure all screws Note Tighten blade...

Страница 8: ...rubber washer inside glass shade over center hole Raise glass shade in order to guide pull chains through corresponding holes in glass shade Align hole in center of glass shade with threaded rod on li...

Страница 9: ...omer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season DOWN position in summer diagram 2 UP position in winter diagram 3 A...

Страница 10: ...292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY LITEX INDUSTR...

Страница 11: ...entilador P g 5 Colocaci n del bastidor del motor P g 5 Colocaci n de las aspas P g 6 Instalaci n del juego de luz P gs 6 7 Verificaci n del funcionamiento del ventilador P g 8 Localizaci n de fallas...

Страница 12: ...les principales del ventilador Si el calibre del cable de la casa es superior al 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno...

Страница 13: ...ontaje 1 unidad b bastidor del motor 1 unidad c unidad del motor 1 unidad d brazo para el aspa 5 unidades e aspa 5 unidades f conectador para el juego de luz 1 unidad g pantalla de vidrio 1 unidad h p...

Страница 14: ...rados 144 pies cuadrados ON OFF ON OFF Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO ADVERTENCIA...

Страница 15: ...escalera y para que le suba el ventilador cuando usted ya est preparado en la escalera para colgarlo PRECAUCION Asegurarse de que la caja de salida est conectada a tierra como es debido y que exista u...

Страница 16: ...a montaje del motor y arandelas planas tornillos para el bastidor del motor tornillos para el bastidor del motor bastidor del motor soporte de montaje Temporalmente subir el bastidor del motor al sopo...

Страница 17: ...los dem s brazos para las aspas Apretar bien todos los tornillos Nota Apretar los tornillos para los brazos para el aspa dos veces al a o 8 Colocaci n de las aspas 9 Instalaci n del juego de luz Quit...

Страница 18: ...enas de encendido por los agujeros correspondientes en la pantalla de vidrio Alinear el agujero de en medio de la pantalla de vidrio con la varilla roscada en el conectador para el juego de luz y con...

Страница 19: ...n Localizaci n de fallas para resolver cualquier asunto antes de comunicarse con el Servicio al Cliente Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que...

Страница 20: ...1 A O LITEX INDUSTRIES LTD reemplazar o reparar cualquier ventilador que tenga funcionamiento deficiente debido a defectos en los materiales o trabajo manual Comunicarse con el Servicio al Cliente al...

Отзывы: