3. Installation Preparation.
4. Hanging Bracket Installation.
page 3
ON
OFF
ON
OFF
hanging bracket
spring washers
outlet box screws
flat washers
Turn off circuit breakers to current fixture from breaker
panel and be sure operating light switch is turned to the
OFF position.
WARNING:
Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING:
When using an existing outlet box, be sure the
outlet box is securely attached to the building structure and
can support the full weight of the fan. Ensure outlet box is
clearly marked "Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do so can
result in serious injury.
CAUTION:
Be sure outlet box is properly grounded and that a
ground (
GREEN
or bare) wire is present.
Partially loosen screws in slotted holes on opposite sides of
canopy. Remove the other 2 screws--
save for later use
. Twist
canopy to remove hanging bracket from canopy.
Install hanging bracket to outlet box using original screws,
spring washers and flat washers provided with new or
original outlet box.
*
Arrange electrical wiring around the
back of the hanging bracket.
*Note
: It is very important that you use the proper hardware
when installing the hanging bracket as this will support the
fan.
Vaulted ceiling
angle is not to
exceed 25 degrees.
downrod
installation
flushmount
installation
7 feet
(2.13 m) (76 cm)
30
inches
12 ft. - 20 ft.
(3.66 m - 6.1 m)
(3.66 m - 6.1 m)
blade edge
To prevent personal injury and damage, ensure that
the hanging location allows the blades a clearance
of 7 feet (2.13 m) from the floor and 30 in (76 cm)
from any wall or obstruction.
This fan is suitable for room sizes up to 400 square
feet (37.2 square meters).
Installation requires these tools:
Phillips screwdriver, flathead screwdriver, adjustable
pliers or wrench, stepladder, wire cutters, and rated
electrical tape.
This fan can be mounted with a
downrod
on a
regular (no-slope) or vaulted ceiling. The hanging
length can be extended by purchasing a longer
downrod (0.5 in /1.27 cm diameter). Other
installation, such as
flushmount
, is
not
available
for this fan.
12 f
t.
- 20 f
t.