6. Wiring.

WARNING

: Turn off circuit breakers to current fixture 

from breaker panel and be sure switch is turned to the 
OFF position.

 
CAUTION

Be sure outlet box is properly grounded and 

that a ground wire (

GREEN

 or Bare) is present.

 

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to below, please use a qualified electrician.

 
Note: 

Excess lead wire length from the fan can be cut 

to the desired length and then stripped.

 

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK 

and

 BLUE

 wires from fan to 

BLACK

 

wire from ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from 

fan to 

BARE

/

GREEN

 wire from ceiling with wire 

connector provided.

 

If you intend to control the fan light with a separate 
light switch, connect 

BLUE

 wire from fan to the 

BLACK

 

(or 

RED

) supply from the independent switch. 

 

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

 

This fan is remote control adaptable (remote control sold 
separately). 

Note

: Only remote controls approved for 

DAMP locations can be used with this fan.

wire

connector

black

white

black supply wire

ground
(green
or bare)

white supply wire

ground 
(green or bare)

*

5. Fan Assembly. (cont.)

With the hanging bracket secured to the outlet box and 
able to support the fan, you are now ready to hang your 
fan. Grab the fan firmly with two hands. Slide downrod 
through opening in hanging bracket and let hanging ball 
rest on the hanging bracket. Turn the hanging ball slot 
until it lines up with the hanging bracket tab.

 
WARNING

: Failure to align slot in hanging ball with tab in 

hanging bracket may result in serious injury or death.

 
Tip:

 Seek the help of another person to hold the 

stepladder in place and to help lift the fan up to you once 
you are set on the ladder. 

 

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be necessary 
to use a heavy duty wood screw, washer and lock washer 
(not supplied) with the safety cable loop. If necessary, 
adjust the loop at the end of the safety cable. The loop at 
the end of the safety cable should just fit over the threads 
on the wood screw. 

Test safety cable by pulling on loose end 

of cable with pliers. If the safety cable slips, the loop must be 
adjusted tighter.

 Extra cable slack can be left in ceiling area. 

motor housing

safety cable

hanging ball slot

wood ceiling joist

wood screw

and washer

safety cable loop

hanging bracket tab

black

white

blue

from fan

from

ceiling

Содержание Propel PPL24

Страница 1: ...ur Fan pg 3 Parts Inventory pg 3 Installation Preparation pg 4 Hanging Bracket Installation pg 4 Fan Assembly pgs 5 6 Wiring pg 6 Canopy Assembly pg 7 Blade Assembly pg 7 Light Kit Assembly pg 8 Testi...

Страница 2: ...has come to a complete stop Note If using remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not insert anything between the fan blades while they are rotat...

Страница 3: ...de 1 piece l hardware packs page 3 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish...

Страница 4: ...around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan pag...

Страница 5: ...threaded end of downrod and pull extra wire slack from the upper end of the downrod Refer to diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with ho...

Страница 6: ...eparately Note Only remote controls approved for DAMP locations can be used with this fan wire connector black white black supply wire ground green or bare white supply wire ground green or bare 5 Fan...

Страница 7: ...ble the blades If screws are overtightened blades may crack and break Locate 24 blade attachment screws in hardware pack Hold blade arm up to blade and align holes Insert 4 blade attachment screws wit...

Страница 8: ...atching up the colors on the male plug with the colors on the female plug for correct fit Be sure that plugs connect securely Carefully arrange wiring within fitter plate Align holes in light kit fitt...

Страница 9: ...hooting section to solve any issues before contacting Customer Service Turn fan completely off before moving the reverse switch located on the light kit fitter Set reverse switch to recirculate air de...

Страница 10: ...which has faulty performance due to a defect in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade We w...

Страница 11: ...l ventilador P gs 5 6 Instalaci n el ctrica P g 6 Colocaci n de la cubierta decorativa P g 7 Colocaci n de las aspas P g 7 Instalaci n del juego de luz P g 8 Verificaci n del funcionamiento del ventil...

Страница 12: ...reductor de luz de gama completa El usar un interruptor con reductor de luz de gama completa para controlar la velocidad del ventilador causar un zumbido recio del ventilador Nota Este ventilador s s...

Страница 13: ...rreter a p gina 3 1 Desempaquetado del ventilador Abrir el empaque cuidadosamente Sacar los art culos del embalaje Sacar el motor y ponerlo en una alfombra o en el embalaje para evitar rayar el acabad...

Страница 14: ...agar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO ADVERTENCIA El no desconectar el suministro de fuerza...

Страница 15: ...os para el perno y la clavija en el tubo con los del cuello asegurarse de que no se tuerzan los cables Volver a introducir el perno y la clavija que se quitaron anteriormente Apretar los tornillos de...

Страница 16: ...itos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO PRECAUCI N Asegurarse de que la caja de salida est conectada a tierra co...

Страница 17: ...quebrarse Localizar los 24 tornillos para fijar las aspas en uno de los paquetes de art culos de ferreter a Agarrar uno de los brazos para las aspas y juntarlo con una de las aspas para alinear los ag...

Страница 18: ...de exterior de la placa de conexi n Conectar el enchufe macho del bastidor del motor al enchufe hembra del conectador para el juego de luz haciendo coincidir los colores en el enchufe macho con los de...

Страница 19: ...a la secci n Localizaci n de fallas antes de comunicarse con el Servicio al cliente Apagar el ventilador completamente antes de mover el interruptor de reversa que se encuentra en el conectador para...

Страница 20: ...reparaci n Esta garant a no se aplica cuando el ventilador tenga da os por abuso mec nico f sico el ctrico o por agua resultando en su mal funcionamiento Se exenta espec ficamente el deterioro en el...

Отзывы: