SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit 

panel before you begin the fan installation or before servicing the fan or installing accessories.

1.         

READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN 

AND SAVE THESE INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp 

edges.
2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, 

and ANSI/NFPA 70-1999.  If you are unfamiliar with electrical wiring or if the house/building wires are 
different colors than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at 

least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips.  The fan should 
be mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or 
other upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted and capable of supporting at 

least 35 pounds (16 kilograms).  The box must be supported directly by the building structure.  Use only 
CUL (Canada) or UL (USA) listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked 

"Acceptable for Fan Support of 15.9 kg (35 lb) or less," and use the mounting screws provided with the outlet 
box.  Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support 
and may need to be replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan 

are designed to accept only one12 gauge house wire and two lead wires from the fan. If your house wire is larger 
than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires, consult an 
electrician for the proper size wire connectors to use.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be CUL 

(Canada) or UL (USA) listed and marked suitable for use with the model fan you are installing.  Switches 
must be CUL (Canada) or UL (USA) general use switches.  Refer to the instructions packaged with the 
light kits and switches for proper assembly.

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up 

into the outlet box.  The wires should be spread apart with the grounded conductor and the 
equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of electrical shock or fire, do not use this fan with any solid state speed control 

device or control fan speed with a full range dimmer switch.  [Using a full range dimmer switch to control fan 
speed will cause a loud humming noise from fan.] (

Note

:  This fan 

is

 suitable for use with remote control.)

8.        Do not operate the reverse switch until fan has come to a complete stop.
9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after 

installation.  Do not insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or 

cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened 

cloth will be suitable for most cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts OTHER 

than those provided with this fan will void the warranty.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all 

possible conditions and situations that may occur.  It must be understood that common sense and caution are 
necessary factors in the installation and operation of this fan.

Содержание BRX52

Страница 1: ... Code pg 10 Remote Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement pg 11 net weight of fan 26 40 lb 11 98 kg READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE PRINTED IN CHINA Installation Guide For models GM56ABZ5LK GM56BNK5LK GM56ESP5LK E192641 Gambrel Federal regulations require ceiling fans with light kits manufactured or imported after ...

Страница 2: ...12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL Canada or UL USA listed and marked suitable for use with the model fan you are installing Switches must be CUL Canada or UL USA general use ...

Страница 3: ... pieces o wall control 2 pieces p plate 1 piece q remote control cover 1 piece r faceplate 3 pieces s blade 5 pieces t hardware packs page 2 Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts...

Страница 4: ...stalling on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the hanging bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan Vaulted ceiling angle is not to exceed 25 degrees downrod installation flushm...

Страница 5: ...agram 2 Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with smooth side toward the motor housing Thread safety cable and wires through hanging ball then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of downrod and raise han...

Страница 6: ... tighter Extra cable slack can be left in ceiling area motor housing wood ceiling joist hanging ball slot hanging bracket tab safety cable wood screw and washer safety cable loop 6 Wiring CAUTION Be sure outlet box is properly grounded and that a ground wire GREEN or Bare is present Make sure all electrical connections comply with Local Codes or Ordinances and the National Electrical Code If you a...

Страница 7: ...rmly onto front of wall control Attach wall control to outlet box and secure with screws from original wall switch Attach plate included to wall control using 2 screws provided with the wall control wiring for wall control black OUT to fan green black AC IN from breaker box black TO POWER supply black green green bare bare ground ground green bare ground outlet box wall control face plate 12V batt...

Страница 8: ... twice a year 9 Light Kit Assembly Optional motor housing plastic motor lock switch housing plate blade arm blade arm screws lock washers Remove 1 screw from fitter plate on underside of motor and partially loosen the other 2 screws Align slotted holes in switch housing plate with loosened screws in fitter plate allowing molex connections from motor housing to come through hole in middle of switch...

Страница 9: ...sing cap with holes in switch housing plate Attach light kit fitter to switch housing plate with 3 screws that were previously removed Secure all 3 screws with Phillips screwdriver Install 2 medium base 13 watt compact fluorescent bulbs included Important When replacing bulbs please allow bulbs and glass shade to cool down before touching Remove finial finial plate and threaded washer from bottom ...

Страница 10: ...L bulbs are NOT compatable for use with dimmer controls Refer to diagram 2 Attach black faceplate to front of wall control press down firmly Refer to diagram 3 Align holes in wall control with posts located on inside of TOP part of remote control cover and press together firmly Place wall control into BOTTOM part of remote control cover aligning posts in top of remote control cover with post holes...

Страница 11: ...nt of the handheld remote control for 5 seconds or until light blinks twice Test the light and fan functions to confirm the learning process is complete see Section 13 below handheld remote control It is recommended that you test fan before finalizing installation Restore power from circuit box and light switch if applicable Test wall control optional installation by locating ON OFF slider switch ...

Страница 12: ...d whatsoever This limitation as to consequential damages shall not apply in states where prohibited Problem Fan fails to operate Solutions 1 Check wall switch to fan wall control 2 Check to be sure wall control optional use is wired properly 3 Check to be sure fan is wired properly 4 Learning process between fan handheld remote control and if applicable wall control may not have been successful an...

Страница 13: ...tivar el código Pág 10 Funcionamiento del control remoto Pág 10 Verificación del funcionamiento del ventilador Pág 10 Localización de fallas Pág 11 Garantía Pág 11 Piezas de repuesto Pág 11 peso neto del ventilador 11 98 kg 26 40 lb IMPRESO EN CHINA LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA UTILIZACION FUTURA Guía de instalación Para modelos GM56ABZ5LK GM56BNK5LK GM56ESP5LK E192641 Gambrel El reg...

Страница 14: ...calibre del cable de la casa es superior al 12 o hay más de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tamaño correcto de conectores para cable que se debe usar 5 Los diagramas eléctricos son únicamente para referencia Los juegos de luz que no se incluyen con el ventilador deben tener...

Страница 15: ...otor 1 unidad h pantalla de vidrio 1 unidad i arandela con rosca fijada de antemano al conectador para el juego de luz 1 unidad j placa del adorno con rosca fijada de antemano al conectador para el juego de luz 1 unidad k adorno con rosca fijado de antemano al conectador para el juego de luz 1 unidad l placa de la caja de encendido 1 unidad m cubierta de la caja de encendido 1 unidad n brazo para ...

Страница 16: ...do colocar el soporte de montaje con la abertura dirigida hacia la parte alta del techo Arreglar el alambrado eléctrico los cables en la parte de atrás del soporte y lejos de la abertura del soporte Nota Es muy importante usar los artículos de ferretería correctos al instalar el soporte de montaje puesto que sirve para sostener el ventilador El ángulo de inclinación de un techo abovedado no puede ...

Страница 17: ... el tubo Referirse al diagrama 3 Nota La tapa de la cubierta decorativa tiene que voltearse para que el lado liso quede hacia el bastidor del motor Pasar los cables y el cable de seguridad por la bola que sirve para colgar luego deslizar la bola que sirve para colgar sobre el tubo la parte de arriba del tubo debe tener el agujero para el tornillo de fijación en ese extremo usar ese agujero al colo...

Страница 18: ...ar el bucle de nuevo Se puede poner el cable en exceso en el área del techo ranura en la bola que sirve para colgar parte saliente del soporte de montaje viga de madera cable de seguridad bucle del cable de seguridad bastidor del motor tornillo para madera y arandela 6 Instalación eléctrica PRECAUCION Asegurarse de que la caja de salida esté conectada a tierra como es debido y que exista un conduc...

Страница 19: ... se puede determinar apagando y prendiendo el equipo se le urge al usuario a intentar rectificar la interferencia tomando una o más de las medidas que siguen Orientar la antena de nuevo o localizarla en otro sitio Aumentar la separación entre el equipo y el receptor Conectar el equipo a un tomacorriente en un circuito distinto al cual está conectado el receptor Solicitar ayuda del distribuidor o u...

Страница 20: ...nillos y arandelas para fijar las aspas en uno de los paquetes de artículos de ferretería Agarrar uno de los brazos para las aspas y juntarlo con una de las aspas para alinear los agujeros Introducir 3 tornillos para fijar las aspas junto con las arandelas con los dedos primero y luego apretar los tornillos bien con un destornillador de estrella Phillips Repetir el procedimiento con las demás aspa...

Страница 21: ...dor para el juego de luz Conectar el cable AZUL o NEGRO de la placa de la caja de encendido al cable NEGRO del conectador para el juego de luz Asegurarse de que las conexiones tipo molex se conecten bien con un clic Alinear los agujeros en la cubierta de la caja de encendido con los agujeros en la placa de la caja de encendido Sujetar el conectador para el juego de luz a la placa de la caja de enc...

Страница 22: ...Referirse al diagrama 3 Alinear los agujeros en el control de pared con los postes que se encuentran adentro de la parte SUPERIOR de la cubierta del control remoto y apretar fijamente Colocar el control de pared dentro de la parte INFERIOR de la cubierta del control remoto alineando los postes en la parte superior de la cubierta del control remoto con los agujeros para los postes en la parte infer...

Страница 23: ...r las instrucciones de la sección 11 más arriba 12 Funcionamiento del control remoto Interruptor corredero ON OFF ENCIENDE y APAGA el control de pared el interruptor no funciona en el control de mano Botón HIGH pone el ventilador en velocidad ALTA Botón MED pone el ventilador en velocidad MEDIA Botón LOW pone el ventilador en velocidad BAJA Botón OFF APAGA el ventilador Botón L1 no se aplica para ...

Страница 24: ...s 1 Inspeccionar el interruptor de pared del ventilador control de pared 2 Verificar la instalación eléctrica del control de pared uso opcional 3 Verificar la instalación eléctrica del ventilador 4 Es posible que no tuvo éxito el proceso de aprendizaje entre el ventilador el control remoto de mano y si se aplica el control de pared y que no se activó el código Desconectar la electricidad y repetir...

Отзывы: