E-Z 50 Melter Part Manual
Troubleshooting
Chapter 7
©2017 by Crafco, Inc. All Rights Reserved……….……………………………………………………….…Troubleshooting 7-1
7.0 Burner Troubleshooting
7.1.1 Symptom: Pilot Will Not Light
Table 7-1 Pilot will not Light
Step
Possible Cause
If…
1
Low fuel pressure
Yes, Adjust pressure to 12” WC (.43 PSI)
No, Go to Step 2
2
Orifice plugged
Yes, Clean orifice
No, Go to Step 3
3
Thermopile dislocated/or faulty
Yes, Adjust so that ¾” of tip is exposed to
igniter flame. See
Figure 7.1
7.1.2 Symptom: Burner Will Not Light
Table 7-2 Burner will not Light
Step
Possible Cause
If…
1
Low fuel pressure
Yes, Adjust pressure to 12” WC (.43 PSI)
No, Go to Step 2
2
Pilot not lit
Yes, Light pilot
No, Refer to Crafco Service Technician
7.2
Troubleshooting Sealant Flow
7.2.1 Symptom: Sealant Will Not Flow
Table 7-3 Sealant will not Flow
Step
Possible Cause
If…
1
Sealant Temperature too low
Yes, Allow material to heat longer
No, Go to Step 2
2
Old material remains in pour spout
Yes, Heat pour spout to liquefy old material
Figure 7.1
Содержание E-Z 50
Страница 1: ...Parts Manual 26211 Revision C Melter Applicator...
Страница 3: ......
Страница 6: ......
Страница 8: ......
Страница 12: ......
Страница 16: ......
Страница 37: ...2017 Crafco Inc...