19
3.3.2 AC and ground connection
The following describes how to connect the AC output and grounding
cables between the inverter and the public power grid:
(1) Use the recommended cables:
L1 (Line 1), L2 (Line 2), L3 (Line 3), Neutral and Gnd (Equipment
grounding conductor)
:
8AWG copper cored soft cables
(2) Cable making for AC output:
(a) Strip the skin 0.4 inch off the cables as shown in Figure 3-14:
Figure 3-14 Diagram for wire stripping of AC output
(c) Crimp the terminal as shown in Figure 3-15:
Figure 3-15 Diagram for terminal crimping of AC output
(3) Cable making for grounding:
(a) The Gnd cable (Equipment grounding conductor) is recommended to
be green or green with continuous yellow stripes, per National
Electrical Code. Strip the skin 0.4 inch off the cables as shown in
Figure 3-16:
Figure 3-16 Diagram for wire stripping of grounding conductor