33
SPICommErr
Figure 4-6 Fault indication interface
LCD screen will display different mode interfaces based on the operation
modes of the inverter. There are four operation modes: startup system check
mode (as shown in Figure 4-3), stand-by mode (as shown in Figure 4-4),
normal operation mode (as shown in Figure 4-5, the switching time between (a)
and (b) is 5 seconds), and fault mode (as shown in Figure 4-6).
The default indication interface mainly indicates PV voltage, PV current,
grid voltage, instant power, daily generated power and time information under
normal operation.
The fault information of the most recent / current fault will be indicated on
the LCD screen when the inverter is in fault mode.
4.3.2 Menu functions
LCD screen displays “default indication interface” when the inverter is in
operation mode. Press
ESC
in this interface to escape the default interface
and enter the main operation interface. The main operation interface is shown
in Figure 4-7.
→
1 OP.Info
2 Alarm
3 History
4 Setting
5 Dispatch