o
peRaTion
32
BA_v2_colibri_ccTalk_EN_1-0
To assign a coin type/token to coin channel 9‑16 or 25‑32, proceed as follows:
If you use the bottom switch block to inhibit individual coins, make a note of
the current switch settings so that you can restore them afterwards for normal
operating mode.
1
Unhook the coin validator from the machine.
2
Set DIL switches S2.1-10 downwards to OFF.
3
Set DIL switch S2.9 upwards to ON.
The device is in the teach mode for teaching the coin
channels.
4
Enable the coin channel to be taught (9‑16/25‑32, here:
11/27) by setting the corresponding DIL switch (S2.1‑8,
here: S2.3) upwards to ON.
5
If necessary, remount the coin validator in the machine.
6
Insert at least 10 coins of the new coin type/token into the coin validator or machine.
Insertion of the tenth coin is confirmed by one‑off activation of the acceptance gate (a brief
clicking noise). Further coins can be inserted.
If there is no signal after the 10
th
coin has been inserted, the coins inserted
cannot be used.
7
If necessary, unhook the coin validator from the machine again.
Now you can save the measured values generated by the inserted coins with a normal (a) or a
wide (b) acceptance band. A wide acceptance band presents itself if you only have available a
limited selection of tokens for teaching.
To save with the normal acceptance band:
8a
Set DIL switch S2.9 downwards back to OFF.
The system indicates successful saving with a single
actuation of the acceptance gate and an error at saving
with a double actuation (a brief clicking noise in each case) if the acceptance band of the
inserted coins and that of an already programmed coin channel overlap or the generated
measured values are too different and the tolerances would be too high, for example.
To cancel the operation, first set the DIL switch of the corresponding coin channel
(S2.1-8, here: S2.3) and then DIL switch S2.9 downwards to OFF.
S2
S2
S2
S2