background image

s

afeTy

 

insTRucTions

12

BA_v2_colibri_ccTalk_EN_1-0

Safety instructions

Before starting up the device for the first time, please read these instructions and in particular 

the safety instructions carefully at least once. This is to ensure that you have understood the 

contents of this manual and how to operate the coin validator.

3.1 

Proper use

The v

2

 colibri electronic 3.5“ coin validator with serial ccTalk interface is for use in entertainment, 

vending and service machines with a serial ccTalk interface and is intended to check the coins 

that are inserted in the machines for specific properties and to either accept or reject them. Use 

the coin validator exclusively for this purpose. Under no circumstances can the manufacturer 

be held liable for any damage or loss resulting from improper use of the device.

The coin validator has been built in accordance with state-of-the-art standards and the recognized 

safety rules. Nevertheless, this equipment can constitute a source of danger. Please observe 

therefore the following safety instructions.

3.2 

Protecting persons and equipment

 

The coin validator must only be connected by a trained electrician.

Use the coin validator only in accordance with its proper use. Under no circumstances 
can the manufacturer be held liable for any damage or loss resulting from improper 
use of the device.

 

The coin validator PCB is fitted with components which may be damaged beyond repair 

by electrostatic discharges. Please observe the handling instructions for components 
exposed to the risk of electrostatic discharge.

Select the correct voltage for the coin validator (see label).

Never pull the connecting cable of the coin validator from the machine when a voltage 
is applied.

Pull the mains plug of the machine before installing, cleaning or removing the coin 
validator.

Please consult Crane Payment Solutions if you intend to make additions or modifications 
to the device that go above and beyond the modifications described here.

Keep water and other liquids away from the coin validator.

 

Please dispose of the device correctly at the end of its service life.

We reserve the right to make technical modifications to the device which are not 

covered by these instructions!

Содержание V2 COLIBRI 36B Series

Страница 1: ...ruchthof 6 21614 Buxtehude Germany Web info craneps com www craneps com Phone 49 0 41 61 729 0 Fax 49 0 41 61 729 115 08 12 WP Hns Roe BA_v2_colibri_ccTalk_EN_1 0 Operating Instructions 3 5 Coin Valid...

Страница 2: ......

Страница 3: ...2 Communication protocol 10 2 2 2 3 High speed acceptance Casino mode 11 2 2 2 4 Protocol encryption 11 3 Safety instructions 12 3 1 Proper use 12 3 2 Protecting persons and equipment 12 4 Design 13 4...

Страница 4: ...ch mode 23 6 Start up 24 6 1 Installing the coin validator in the machine 24 6 2 Mounting the 3 fold sorter s2 SSD 3000 25 6 2 1 on the v2 colibri top entry version 25 6 2 2 on the v2 colibri front en...

Страница 5: ...2 Which device functions can be set 37 10 Technical data 39 10 1 Device data 39 10 2 Interfaces 40 10 2 1 v2 colibri machine 40 10 2 1 1 Pin assignment 40 10 2 1 2 Implemented ccTalk commands 40 10 2...

Страница 6: ......

Страница 7: ...Revision protocol BA_v2_colibri_ccTalk_EN_1 0 7 1 Revision protocol Version Revision Chapters sections concerned...

Страница 8: ...nded Index reduce the search for specific explanations 2 1 1 Text conventions To make it easier for you to navigate within these instructions and to operate the device the symbols below are printed in...

Страница 9: ...ckly as possible to new false coins and to make your individual settings the coin validator can be configured on site in the machine using a service tool or in the workshop via a PC programming statio...

Страница 10: ...sert the coin from the side into the device and it is also returned at the side should it not be accepted cf Chap 4 2 Coin path p 15 On this coin validator you can push on the optional NRI MINI or MID...

Страница 11: ...nd needs to accept coins particularly quickly up to 6 coins per second In Casino mode the v2 colibri runs in favour of fast coin acceptance without accepted coin sensing cf Chap 5 3 Accepted coin sens...

Страница 12: ...erve therefore the following safety instructions 3 2 Protecting persons and equipment The coin validator must only be connected by a trained electrician Use the coin validator only in accordance with...

Страница 13: ...channel assignment cf Chap 4 4 Switching functions coin channel assignment sticker p 16 10 Interface service configuration 11 Interface for other v2 colibri series only 12 Interface machine ccTalk 13...

Страница 14: ...ent sticker p 16 10 Interface service configuration 11 Interface for other v2 colibri series only 12 Interface machine ccTalk 13 Switch blocks 1 Coin insert funnel 2 Coin return button 3 Flight deck 4...

Страница 15: ...path Fig 3 Coin path of top entry version standard coin outlet on the left and inverted coin outlet on the right Cash box sorting device Return Return Cash box sorting device Fig 4 Coin path of front...

Страница 16: ...m for the workshop and the place of use 1 Device type 2 Bar code 3 Ordering code 10 digit order number 4 digit device serial number 4 digit 4 Machine interface 5 Nominal voltage 6 Date of manufacture...

Страница 17: ...annel 8 accepts inhibited S1 9 Operating mode Standard mode Casino mode S1 10 Memory block 0 1 4 5 2 Switching functions S2 1 10 DIL switch Function OFF ON S2 1 Coin channel 9 accepts inhibited S2 2 C...

Страница 18: ...e return lever opens the measurement and validation area of the coin validator so that all objects in the coin validator are directed to the return area Devices with front entry via a front plate do n...

Страница 19: ...ithsimilarmeasuredvalues canberejectedifthenormalchannelisdisabled cf Chap 7 2Inhibitingcoins activatingnarrowcoinchannel p 29 However narrow and super narrow coin channels also have a lower acceptanc...

Страница 20: ...xternalsortingdeviceandthatacceptance is not tampered with an accepted coin sensor light barrier checks before the cash box coin exit Fig 1 6 Fig 2 6 whether the inserted coin drops without hindrance...

Страница 21: ...lidator is sorting an accepted coin the sorting time it cannot accept any further coins unless the same ccTalk sorting path is addressed If external sorting is no longer needed and the sorting time is...

Страница 22: ...sorter s2 SSD 3000 p 25 R CKG ABE RECHTS M ITTE LINKS Fig 8 Sorting and return chutes s2 SSD 3002 5 6 Coin inhibition activation of narrow coin channels If coins are no longer to be accepted for paym...

Страница 23: ...locking with the controller you can use the two switch blocks on the coin validator to inhibit individual coin channels or groups of coin channels on site cf Chap 7 2 Inhibiting coins activating narro...

Страница 24: ...rect voltage for the coin validator see label Neverpulltheconnectingcableofthecoinvalidatorfromthemachine when a voltage is applied Pull out the mains plug of the machine before installing or dismount...

Страница 25: ...ting chute s2 SSD 3003 Return chute behind the right hand sorting chute Mounting the sorter will be explained using the s2 SSD 3002 as an example 1 Fasten the mounting frame Fig 10 1 using the three s...

Страница 26: ...Start up 26 BA_v2_colibri_ccTalk_EN_1 0 Fig 10 Connecting the top entry version of the v2 colibri to the s2 SSD 3002 3 fold sorter 1 2 2 3 5 5 5 4...

Страница 27: ...t onto the coin validator 4 Fasten the sorter Fig 11 3 on the coin validator with the screw Fig 11 4 5 Connect the sorter Fig 11 3 to the coin validator by means of the 10 pin sorting con nector Fig 1...

Страница 28: ...t later p 37 The exact function of the settable device options is described in Chap 5 Function p 19 7 1 Selecting memory block for double block data management only Ifthecoinvalidatoristoaccesstheothe...

Страница 29: ...Coin channel 3 accepts inhibited S1 4 Coin channel 4 accepts inhibited S1 5 Coin channel 5 accepts inhibited S1 6 Coin channel 6 accepts inhibited S1 7 Coin channel 7 accepts inhibited S1 8 Coin chan...

Страница 30: ...annels 3 and 10 are no longer used If one normal and one narrow coin channel are programmed for a coin type on the coin validator you must inhibit the normal coin channel as described above to activat...

Страница 31: ...nction OFF ON S2 1 Teach mode Teach coin channel 9 S2 2 Teach mode Teach coin channel 10 S2 3 Teach mode Teach coin channel 11 S2 4 Teach mode Teach coin channel 12 S2 5 Teach mode Teach coin channel...

Страница 32: ...e gate a brief clicking noise Further coins can be inserted If there is no signal after the 10th coin has been inserted the coins inserted cannot be used 7 If necessary unhook the coin validator from...

Страница 33: ...y remount the coin validator in the machine 11 Switch power off and on again 12 Enable the taught coin channel here 11 27 via the control system and adapt sorting if necessary The coin validator will...

Страница 34: ...ing mode by simply resetting the top switch block Set DIL switch S1 9 upwards to ON ThedevicenowoperatesinCasinomodewithfastcoin acceptance of five to six coins per second Tripping time of the accepta...

Страница 35: ...ter Moisten the cloth only slightly to prevent fluid from entering the device This would damage the PCB Do not use solvents or scouring agents that could affect the plastic and appearance of the devic...

Страница 36: ...at the return lever button has not been permanently pressed by mistake Coin runway dirty Open the flight deck and clean the coin runway cf Chap 8 1 Cleaning the coin runway p 35 Coin inhibited Ensure...

Страница 37: ...ing the complete coin and device configuration using the data blocks currently made available by Crane Payment Solutions data block upload The WinEMP application identifies the coin validator that is...

Страница 38: ...and coin type Definition of a sorting time Long term coin deactivation Teach mode via Activating deactivating teach mode Activating deactivating teach channels New coins tokens generation of a new acc...

Страница 39: ...g to cctalk Serial Communication Generic Specification Money Controls For pin assignment see Chap 10 2 1 v2 colibri machine p 40 Sorting interface 2 4 parallel outputs open collector cf Chap 10 2 2 v2...

Страница 40: ...t at www cctalk org 10 2 1 2 Implemented ccTalk commands Header Command Function No of data bytes expected returned Optional ACMI deviations for Italian gambling machine market 254 Simple poll 0 0 253...

Страница 41: ...ode table p 42 228 Modify master inhibit status 1 0 227 Request master inhibit status 0 1 222 Modify sorter override status 1 0 221 Request sorter override status 0 1 219 Enter new PIN 4 0 no function...

Страница 42: ...n 14 Credit sensor blocked 16 Credit sequence error 20 Coin on string mechanism activated 126 Return lever motor timeout Sorter failed Coin was routed to unintended path The following coin event will...

Страница 43: ...eived data Byte 1 No of coins inserted Byte 2 Status code 252 teaching process aborted see header 202 253 teaching error overlapping with existing acceptance band coin type not found 254 teaching in p...

Страница 44: ...black 120 x 60mm with white return button 22569 with black return button 23097 10 3 2 Sorters Designation Order no s2 SSD 3001 3002 3003 3004 3 way sorter The order number depends on the version of th...

Страница 45: ...ENRI for G 13 mft Power supply In the machine via transformer In the workshop via 12V power supply with international adapters 33573 26482 34714 Cover WinEMP PC application For diagnosing and updating...

Страница 46: ...nted commands 42 Interface 13 14 39 Standard settings after reset 42 Channels 19 Inhibit 29 Narrow 19 Activating 29 Normal 19 Very narrow 19 Chapter summary 8 Cleaning 35 Coin Inhibit 22 23 Procedure...

Страница 47: ...Instructions 8 Guide chapter contents 8 H Headers implemented ccTalk 42 HENRI 37 Ordering code 45 Homepage NRI 9 HSD 3000 sorter 44 Humidity 39 I Inhibit coins 22 23 Procedure 29 Insert funnel 13 14...

Страница 48: ...Safety instructions 8 12 Serial number 16 Settings 8 28 37 Default after rest ccTalk 42 On site HENRI 37 Software For configuration 37 Update 37 Sorting Chute 13 14 Function 21 Interface 13 14 Order...

Отзывы:

Похожие инструкции для V2 COLIBRI 36B Series