Se
ctio
n
7
- T
ec
h
n
ic
al I
n
fo
rmatio
n
3.
The chamber now lifts and the second motor drives the filter belt and the waste is
scraped into the waste bucket.
7.9.2 Tea Brewing
1.
The tea outlet elbow and baseplate are colour coded blue and the belt is white with
white stitching.
2.
The chamber clamps down onto the base plate and filter, water and tea leaves are
then dispensed. Gravity draws the tea through the filter and it is delivered into the
cup.
3.
The chamber now lifts and the second motor drives the filter belt and the waste is
scraped into the waste bucket.
7.10 Power Supply Units
Warning: Power to the machine should be switched off before covers are removed.
1.
The main power supply unit (PSU) provides power to the machine. it is mounted in the
top right hand side of the COTI machine and can be accessed by removing the top RH
panel. On the LINEA it is mounted in the back of the machine behind the rear cover.
2.
The PSU converts 110V AC to 24V DC to run the Control board, I/O board, valves,
whipper motors, ingredient motors, brewers, etc. fitted to the machine. The solid state
relay is mounted on the PSU chassis and uses a 24V DC switching circuit to provide
110V AC for the heater element.
3.
A secondary PSU converts 110V AC to 12V DC to power the screen.
4.
The Input/output (I/O) board, mounted on the PSU chassis, utilises signals from the
main controller in order to operate valves, whipper motors, dispense head motor,
ingredient motors, brewer motors, etc.
5.
There are three fuses. On the COTI they are mounted adjacent to the power supplies,
on the LINEA they are on the rear panel of the machine.
Heater, 12 amp (T) (ceramic) - Gravity boiler/Espresso boiler - (MDA 12A)
110V AC Auxiliary, 4 amp (glass) - (MDA 4A)
24V DC Output, 3.2 amp (T).
7.11 Mains Filter
A mains filter, mounted on the rear panel, prevents spurious voltages generated by the
machine from reaching the mains supply.
7.12 Coin Mechanism Transformer (For Exec monetary devices
- optional extra - COTI Machines only)
The coin mechanism transformer converts 110V AC to 24V AC for Executive protocol coin
mechanisms and cashless systems. Refer to 7.14 Coin and Card/Key Systems
These machines may be equipped with coin or card/key validation systems using either
Executive protocol or an MDB system. The coin or card/key system informs the vending
114
Содержание COTI
Страница 1: ...Part No 403018 Issue April 2021 Technical Manual From software version 3 7 1 ...
Страница 2: ......
Страница 30: ...Section 3 Programming Mode 20 ...
Страница 33: ...Section 4 Customising the User Interface Technical Manual 13 14 15 16 17 18 19 20 21 22 23 24 23 ...
Страница 35: ...Section 4 Customising the User Interface Technical Manual 7 8 9 10 11 25 ...
Страница 128: ...Section 8 Espresso System 8 2 1 Espresso Water Flow Diagram 118 ...
Страница 148: ...Section 11 Electrical Electronic Diagrams Atlas H Board Pin Connections COTI 138 ...
Страница 150: ...Section 11 Electrical Electronic Diagrams Atlas H Board Pin Connections LINEA 9 10 1 140 ...
Страница 152: ...Section 11 Electrical Electronic Diagrams 11 8 Input Circuit 1 COTI 142 ...
Страница 153: ...Section 11 Electrical Electronic Diagrams Technical Manual 11 9 Input Circuit 2 COTI J2 J7 143 ...
Страница 154: ...Section 11 Electrical Electronic Diagrams 11 10 Input Circuit 1 LINEA 144 ...
Страница 155: ...Section 11 Electrical Electronic Diagrams Technical Manual 11 11 Input Circuit 2 LINEA J2 J7 ORANGE BLUE 145 ...
Страница 156: ...Section 11 Electrical Electronic Diagrams 11 12 Output Circuit 1 COTI 146 ...
Страница 158: ...Section 11 Electrical Electronic Diagrams 11 14 Output Circuit 1 LINEA 148 ...
Страница 162: ...Section 11 Electrical Electronic Diagrams 11 18 Power Circuit LINEA Instant Freshbrew 176 O 244 O 1 2kW 176 O 152 ...
Страница 163: ...Section 11 Electrical Electronic Diagrams Technical Manual 11 19 Power Circuit LINEA Espresso 244 O 1kW 153 ...
Страница 168: ...NOTES 158 ...
Страница 169: ......