Idle Time Seconds - This is the period of inactivity necessary prior to the reboot.
Enter the required period using the displayed numeric keypad and press Save.
5.11.23 Buzzer Settings
This enables the sounds when touching the selection interface buttons to be varied.
1. Buzzer Enabled - This Enables or Disables the buzzer.
2. Buzzer Selection - Select between Low Beep, Medium Beep or High Beep. This is the
length of the tone, reducing it makes it less intrusive in the local environment.
5.11.24 Debug Log Enable
This feature is Enabled or Disabled. When enabled this feature allows a log to be taken of
the events within the machine which can then be sent to [email protected] for
analysis.
The log is taken by inserting a USB stick (on which you have created a folder named “logs”
in the root menu) into the USB 3 socket on the atlas board. When the log has been
downloaded onto the stick the screen will instruct you to remove the USB stick.
Note: THIS FEATURE MUST BE ENABLED TO ALLOW AN MDB LOG TO BE TAKEN. (see
section 5.4.3)
5.11.25 Display OOS Errors
When enabled this feature will display errors on the User Interface seen by the customer.
5.11.26 LED Device Type
This enables the selection of the LED colour scheme.
1. Select the required colour type from those available on the LED Device Type screen to
display the colours available in that type.
2. Selecting Red LED will display a red colour scheme on the Display Screen.
3. Selecting RGB Led type allows various colour schemes to be activated. (if the necessary
hardware is fitted)
5.12 Security Codes
The security code for entry into the Engineer’s Program is factory set so that the engineer
presses the sequence of four numbers on the drink selection interface.
This screen enables these entry and keyless vend codes to be changed.
Note: On no account should the first three codes be altered without first consulting your
supervisor or manager.
1. Enter Pin - by entering the Operator PIN you will be taken into the Operator menu
2. Change Engineer PIN - this displays and enables the pin to be changed for entry into
the Engineer’s program.
3. Change Operator PIN - this displays and enables the pin to be changed for entry into
the Operator’s program.
99
Содержание COTI
Страница 1: ...Part No 403018 Issue April 2021 Technical Manual From software version 3 7 1 ...
Страница 2: ......
Страница 30: ...Section 3 Programming Mode 20 ...
Страница 33: ...Section 4 Customising the User Interface Technical Manual 13 14 15 16 17 18 19 20 21 22 23 24 23 ...
Страница 35: ...Section 4 Customising the User Interface Technical Manual 7 8 9 10 11 25 ...
Страница 128: ...Section 8 Espresso System 8 2 1 Espresso Water Flow Diagram 118 ...
Страница 148: ...Section 11 Electrical Electronic Diagrams Atlas H Board Pin Connections COTI 138 ...
Страница 150: ...Section 11 Electrical Electronic Diagrams Atlas H Board Pin Connections LINEA 9 10 1 140 ...
Страница 152: ...Section 11 Electrical Electronic Diagrams 11 8 Input Circuit 1 COTI 142 ...
Страница 153: ...Section 11 Electrical Electronic Diagrams Technical Manual 11 9 Input Circuit 2 COTI J2 J7 143 ...
Страница 154: ...Section 11 Electrical Electronic Diagrams 11 10 Input Circuit 1 LINEA 144 ...
Страница 155: ...Section 11 Electrical Electronic Diagrams Technical Manual 11 11 Input Circuit 2 LINEA J2 J7 ORANGE BLUE 145 ...
Страница 156: ...Section 11 Electrical Electronic Diagrams 11 12 Output Circuit 1 COTI 146 ...
Страница 158: ...Section 11 Electrical Electronic Diagrams 11 14 Output Circuit 1 LINEA 148 ...
Страница 162: ...Section 11 Electrical Electronic Diagrams 11 18 Power Circuit LINEA Instant Freshbrew 176 O 244 O 1 2kW 176 O 152 ...
Страница 163: ...Section 11 Electrical Electronic Diagrams Technical Manual 11 19 Power Circuit LINEA Espresso 244 O 1kW 153 ...
Страница 168: ...NOTES 158 ...
Страница 169: ......