![Cozzia EC-363C Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/cozzia/ec-363c/ec-363c_maintenance-service-manual_2674657005.webp)
②
Tapping motor fails.
敲击电机坏
③
Main PCB fails.
④
中心板坏
motor.
更换敲击电机
③
Replace main PCB.
更换中心板
08
No response
when pressing
the keys on
the remote
controller.
手控器按键
无反应
①
The terminals and wires are
poorly connected.
接线端或线材接触不良
②
The PCB in the remote
controller fails.
手控器中心板坏
①
Plug
the
terminal
securely or replace the
wires.
将接线端接插到位或更换
线材
②
Replace the remote
controller.
更换手控器
09
Back rest
cannot be
reclined or
raised
不升倒背
①
The terminals of reclining
actuator and wires are poorly
connected.
电动推杆接线端或线材接触不
良
②
The reclining actuator fails.
电动推杆坏
③
Main PCB fails.
④
中心板坏
①
Plug
the
terminal
securely.
将接线端接插到位
②
Replace
reclining
actuator.
更换电动推杆
③
Replace main PCB.
更换中心板
Содержание EC-363C