![Cozzia EC-363C Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/cozzia/ec-363c/ec-363c_maintenance-service-manual_2674657003.webp)
starting and no response by
pressing other keys.
开机揉捏其他按键无效
03
No Width
switchover.
宽度无法切
换
①
The terminals of Width
Inspection on main PCB and
wires are poorly connected.
中心板宽度检测端子线材接触
不良
②
The terminals of Width
Inspection
on
massage
mechanical and wires are
poorly connected.
机芯宽度检测板线材接触不良
③
Width Inspection fails.
宽度检测板坏
④
Main PCB fails.
中心板坏
①
&
②
Plug the terminal
securely or replace the
wires.
端子接插到位或更换线材
④
Replace
the
Width
Inspection.
更换宽度检测板
⑤
Replace the main PCB.
更换中心板
04
No Partial
Function.
无区间功能
①
Height Inspection Terminal or
wire poorly contacts.
高度检测板接线端或线材接触
不良
②
Height
Counting
Subassembly fails.
高度计算组件坏
①
Plug
the
terminal
securely or replace the
wires.
把接线端插到位或跟换线
材
②
Replace
Height
Counting Sub-assembly.
更换高度计算组件