7
Check your local building codes for the proper method of installation. In the absence of local codes, this unit
should be installed in accordance with the
National Fuel Gas Code No. Z223.1-1998 USA
or
CAN/CGA-B149.1/.2
Natural Gas/Propane Code (Canada)
latest edition or the
National Electrical Code ANSI/NFPA No. 70
or the
Canadian Electrical Code CSA C22.1, 1990
or latest version.
-
Before installing built-in side burners in enclosures, copy all product information such as model number,
serial number and type of side burner (e.g. natural gas or LP) and store information in a safe place.
-
If the side burner is installed by a professional installer or technician, be sure that he or she shows you
where your gas supply shut-off is located. All gas lines must have a shut-off that is readily and easily
accessible. If you smell gas, check for gas leaks immediately. Check only with a soap and water solution.
Never check for gas leaks with an open flame.
Notice:
We strongly recommend professional installation of your Coyote side burner. These instructions provide
the measurements necessary to construct a masonry structure to house your outdoor gas side burner.
IMPORTANT:
Gas fittings, regulator, and installer supplied shut-off valves must be easily accessible.
LOCATION OF YOUR SIDE
BURNER:
Locate the side burner only OUTSIDE in a well-ventilated area.
Never locate the side burner in a building, garage,
breezeway, shed or other such enclosed areas without an approved ventilation system
. When in use, the side
burner will generate a lot of smoke. When installing your side burner, select an outdoor location that will ensure
there is adequate area for the smoke to dissipate IN ORDER TO AVOID INHALATION OF POTENTIALLY TOXIC
FUMES.
Ventilation Requirements for Proper Operation of your Coyote Side burner
•
Ventilation for a gas side burner is absolutely mandatory to ensure that your side burner performs as
intended and to ensure the safety of you, your family, and guests. Proper ventilation is necessary to
allow heat inside your side burner to escape and also to allow any gas that has leaked from a tank or
connection to escape before a buildup of such gas can occur and possibly ignite.
Failure to provide proper ventilation will nullify Coyote’s warranty and will
cause a risk of bodily injury or death.
•
If you elect to install your side burner into an island, the island itself must be ventilated properly. Any
such island must have a minimum of 2 vents (but optimally 4 vents) per cabinet that has any sort of gas
supply or connection. Each vent must be at least 20 sq. in in size and have access to outside/fresh air.
Those vents will allow heat that is trapped inside due to wind to be able to dissipate out of the island
vents. However, if the island is not ventilated properly and the wind is coming from the back, then the
heat will try to escape through the easiest exit, which will most likely be through the bottom of the side
burner and front control panel.
•
A simple way to think of what is occurring inside your side burner is that when your burners are on, they
are emitting a flame that creates the heat to cook your food. This heat must exhaust or escape from the
side burner, otherwise you would eventually have a unit that would not only build up intense heat but
also dangerous pressure. This could cause severe damage to not only the side burner but any operators
Locating the Grill
Содержание C1PB