burner body itself. A bottom deck is not required to support the side burner from the bottom. It is also required
that:
A minimum of two ventilation holes in the enclosure, of at least 20 sq. inches in size (per vent), must be
present to help release any leaking gas from the enclosure.
As Propane is heavier than air, for propane side burners locate your vents at the tank valve height
or lower
As Natural Gas is lighter than air, for natural gas side burners locate your vents at the gas
connection height or higher
The counter should be flat and level relative to the floor.
LP TANK STORAGE MUST BE ISOLATED IN A SEPARATE COMPARTMENT FROM THAT
OF THE SIDE BURNER AND IT MUST BE VENTED AS WELL. (RECOMMEND BOTTOM VENTS FOR LP)
The two top illustrations demonstrate how the slide-in type unit is designed to fit into open- front enclosures, and
supported at the Countertop.
Do not install this unit under unprotected flammable surfaces. Do not install or use this appliance
inside a building, garage, or any other covered area. It must not be used in or on recreational vehicles
or boats.
High Elevation Installation and Use
Coyote Side burners are designed to operate most efficiently at 0-2000 feet above sea level. From 2000-4000 feet
above sea level you will not notice any substantial decrease in your heat, although more gas is combusting within the
burners due to less oxygen. Above 4000 feet, you may experience longer cooking times on your side burner than
experienced at sea level. This is due to the air/fuel mixture taking place within the burners. If you have questions or
concerns regarding your location or elevation, please contact Coyote Customer Service for assistance.