25
between the electrode and contact point.
•
Check for loose wire connections to the igniter or electrodes.
•
Check to see if debris is blocking the electrodes.
•
If the igniter is not working, can you light the side burner with a
lighter?
Flare-ups
•
Ensure burner is not placed directly in the path of wind.
Be sure drip pan is clean (do not use aluminum foil on drip pan.)
Note: Some flare-ups may be inevitable if cooking greasy foods.
Yellow Flames
•
Check the burner inlet for obstructions, particularly at air inlets for
each burner.
•
Side burner should not be in an area that is too windy.
Flame blows out on low setting or has
uneven heat distribution.
•
Check for spider webs or insect nest in venturi and clean venturi.
•
Cold side burner needs to be preheated for 5 minutes on high
setting.
•
Venturi may be misaligned and needs to be lined up over orifices.
•
Cold and windy weather will require you to move side burner away
from the wind.
•
Lack of fuel. Check to see cylinder valve is open and cylinder has
fuel.
Low heat with the knob on “HIGH”
•
Check to see if the fuel hose is bent or kinked
•
Make sure the cooking area is clear of dust
•
Check your gas supply and gas pressure.
•
If it is only one burner that appears low, make sure the orifice or
burner is clean.
Burner is Too Hot
•
Excess grease build-up causing grease fires.
•
Damaged or faulty regulator.
Replace with factory authorized parts.
•
Cook on a lower temperature setting.
Flame behind control panel or control
knob area.
IMMEDIATELY shut off cylinder valve and allow side burner to cool.
•
C
heck for spider webs or insect nest in venturi and clean venturi.
•
Gas is leaking from a faulty connection. Tighten connections with an
adjustable wrench and replace damaged parts. Perform a leak test
on all connections before cooking on side burner again.
•
Venturi may be misaligned and needs to be lined up over orifice.
Fire at any connection.
IMMEDIATELY shut off cylinder valve and allow side burner to cool.
•
Gas is leaking from a faulty connection. Tighten connections with an
adjustable wrench and replace damaged parts.
•
Perform a leak test on all connections before cooking on the side
burner again.
Содержание C1PB
Страница 27: ...26 C1PB Parts List...