Glove Grip

The fingers flex slightly and the thumb flexes in towards the palm. This grip makes 

the hand as slim as possible.

8.0   Grip Patterns

Rock Grip

This grip is not a functional grip. The index and little finger remain extended, while 

the middle two fingers flex in towards the palm with the thumb closing over them.

Tripod Grip

The thumb and fingers 1 and 2 are used to hold an object. The thumb and four 

fingers move simultaneously, fingers 3 and 4 flex in towards the palm and fingers 1 

and 2 flex in to meet the tip of the thumb. Active finger tracking ensures a reliable 

and stable grip.

Содержание HAND

Страница 1: ...www covvi com Unit 4 Quayside Business Park Leeds LS10 1DJ 020 3949 9500 Technical Manual THE COVVI HAND...

Страница 2: ...Anything Is Possible...

Страница 3: ...osthetics has historically been very low but as engineers and designers we see this as a challenge to continuously improve our designs to meet the needs of users COVVI started with a blank sheet of pa...

Страница 4: ...Connecting Disconnecting the COVVI Hand 16 6 2 E Paper Screen 18 6 3 System Notifications 19 COVVI Hand Features 21 7 1 Passively Flexing Fingers and Thumb 21 7 2 Integrated Flex Wrist 22 7 3 Water an...

Страница 5: ...1 8 Operating Modes 57 11 9 Grip Tables 58 11 10 User Defined Grips 60 11 11 Grip Switch Triggers 61 11 12 Additional Setup 64 11 13 Changes 67 11 14 Advanced Configuration 68 11 15 Config History 69...

Страница 6: ...ly result in the prosthetic device being rejected which we see as a personal failure In today s world there are so many products and designs that we simply do not need yet in the field of prosthetics...

Страница 7: ...Leeds LS10 1DJ 020 3949 9500 COVPS 1600 Shown CCOUP Coupling Piece CAXCOR Coaxial Core CLAMRG Lamination Ring COVSWC Wall Charger Control Panel COVVI Hand COVPS 1600 Prismatic COVPS 2600 Cylindrical...

Страница 8: ...rn off If for any reason the power does not turn off while charging using the hand can be potentially unsafe Do NOT use the COVVI Hand if a failure occurs as it could cause damage to your patient or o...

Страница 9: ...tion for the hand Do NOT expose the COVVI Hand to an open flame Do NOT expose the COVVI Hand to chemicals such as solvents acids alkalis corrosive substances detergents and similar chemicals as this c...

Страница 10: ...rature 4 F 20 C Humidity Maximum 80 non condensing Pressure 101 3kPa 14 7psi The COVVI Hand is to be used exclusively for upper extremity prosthetic fittings Based on the environmental conditions belo...

Страница 11: ...ically out of the box then slide the rest of the foam pieces along into the gap left by foam piece 1 Lift the hand from the box and remove foam piece 2 from the EQD and foam piece 5 from the fingers T...

Страница 12: ...110 4 5 114 5 4 8 124 Max Chassis Width C 2 76 70 3 75 3 1 80 Diameter of Chassis at Wrist D 1 85 47 1 85 47 1 9 50 Palm Circumference G 7 3 190 7 6 195 7 8 200 Maximum Opening Width Tripod Grip H 4...

Страница 13: ...iew Stainless Steel Finger Pivot E Paper Screen Peek 450g Stainless Steel High Impact Polymer Chassis Stainless Steel Knuckle Cast Aluminium Digit Components Stainless Steel Finger Link Stainless Stee...

Страница 14: ...49 9500 5 0 The COVVI Hand Flexible Glove FSR s in all the Fingertips Touch Screen Compatibility with the Index Finger EQD Electric Quick Disconnect Thicker Palmar Region E Paper Screen Hardened 60A S...

Страница 15: ...VI Hand COVVI Hand Voltage 7 to 8 4V Maximum Current Consumption 5A 1600mAh 8A 2600mAh Device Weight 0 57kg 1 25 lbs Maximum Hand Load Limit A 90kg 198 lbs across knuckle Maximum Hand Load Limit B 32k...

Страница 16: ...ectric current from the batteries Turn the power on once the hand is properly connected to the prosthesis Please see the image below for instructions on how to connect the COVVI Hand to your patient s...

Страница 17: ...onnected properly When you turn the hand on you will hear the start up beep and the E Paper screen will display COVVI followed by the first grip in Table A Once you use the hand every time you turn it...

Страница 18: ...requires no power to display and little power to change display so it doesn t drain the user s batteries When you turn the hand on the E Paper screen will display the following It always shows the cu...

Страница 19: ...press to the dorsal button under two seconds puts the hand into Standby Mode where user inputs from the electrodes have no effect on the hand Pressing the dorsal button again will exit Standby Mode a...

Страница 20: ...llowing warning message and icon will appear If this message appears please disconnect the hand and allow it to dry in a warm dry environment Any function that refreshes the screen for example a grip...

Страница 21: ...have passive flex which increases durability as the spring loaded feature provides impact protection The digits fold out of the way reducing the likelihood of damages and repairs All digits are manufa...

Страница 22: ...ilicone glove with a soft touch coating Powder was added into the index finger for touch screen compatibility which is a reliable method The fingertips are hardened to 60A shore and over moulded into...

Страница 23: ...umb tap which is a quick intuitive way to change grips or tables Laterally tap the side of the thumb to trigger the rocker switch and activate the powered rotation without the need for a myo input The...

Страница 24: ...witch If the next grip is non opposed the thumb will remain in the same position if the next grip is opposed the thumb will rotate to an opposed position For a Right Hand Thumb Tap Pronate Tap the rig...

Страница 25: ...rs flex in towards the palm around an object with the thumb completing the grip by locking over fingers 1 and 2 8 0 Grip Patterns Precision Grip Open Close In precision open the thumb moves to a known...

Страница 26: ...his grip is not a functional grip The index and little finger remain extended while the middle two fingers flex in towards the palm with the thumb closing over them Tripod Grip The thumb and fingers 1...

Страница 27: ...ger Finger Point Grip Fingers 2 3 and 4 flex in towards the palm the thumb closes to a fully flexed position and the index finger remains extended Tap Grip This grip is very similar to the finger poin...

Страница 28: ...ing the mouse button When the close signal is released the index finger will straighten Relaxed Grip The hand is open but the fingers and thumb slightly flex Phone Grip This grip is not a functional g...

Страница 29: ...ystem weight of 104 grams ideal for users with a short residual limb and 1600mAh prismatic flat cells with a system weight of 74 grams and a web connecting the cells This web allows the batteries to b...

Страница 30: ...nit 4 Quayside Business Park Leeds LS10 1DJ 020 3949 9500 9 0 The COVVI Power Supply 1 Battery Silicone Adhesive 1 Battery Dummy Velcro Control Panel Cutting Template Located in the COVPS Box 9 1 What...

Страница 31: ...00 Page 31 www covvi com Unit 4 Quayside Business Park Leeds LS10 1DJ 020 3949 9500 9 0 The COVVI Power Supply AU EU USB C Wall Charger UK US Only use with COVVI Batteries...

Страница 32: ...om the batteries Do NOT attempt to use the prosthetic device while the batteries are charging When the batteries are charging the power will automatically turn off If for any reason the power does not...

Страница 33: ...S10 1DJ 020 3949 9500 9 0 The COVVI Power Supply The 1600mAh Battery is made up of four prismatic cells that can be bent either way along the brown connecting web 9 3 1600mAh Batteries The 2600mAh Bat...

Страница 34: ...r Button on the Control Panel for two seconds to turn the Power Supply on The screen will display COVVI for two seconds and then the current charge level for five seconds The system is now providing p...

Страница 35: ...wo display modes bars or a percentage level To choose the display mode connect the USB C Wall Charger to the Control Panel turn it on and press and hold the Power Button until the screen starts altern...

Страница 36: ...rge Indication 10 blocks equals 100 9 blocks greater than or equal to 90 8 blocks greater than or equal to 80 7 blocks greater than or equal to 70 or or or or 6 blocks greater than or equal to 60 or 5...

Страница 37: ...20 1 block greater than or equal to 10 No blocks less than 10 When the system is charging it will show this screen 9 0 The COVVI Power Supply If there is a fault with the Power Supply the OLED screen...

Страница 38: ...ividual prostheses will differ from patient to patient We recommend the Control Panel is placed on the upper side of the prosthetic socket away from any area which may be loadbearing when carrying hea...

Страница 39: ...be connected to the Control Panel prior to being fitted to the limb or after it is fitted if there is sufficient access space To ensure correct function it is important to inspect the Control Panel ca...

Страница 40: ...nfolded Folded Inches 4 1 x 2 2 x 0 35 4 1 x 0 74 x 0 89 Battery Unfolded Folded mm 104 1 x 55 8 x 8 9 104 1 x 18 8 x 22 9 System Weight 74 grams Humidity Maximum 80 humidity non condensing Charge Tem...

Страница 41: ...Battery Capacity 2600mAh Nominal Voltage 7 4V Maximum Current Draw 8A Peak Battery Size Inches 2 6 x 1 6 x 0 8 Battery Size mm 70 x 40 x 20 System Weight 104 grams Humidity Maximum 80 humidity non co...

Страница 42: ...both Power Supply versions It is imperative that you replace the batteries with those of the same capacity COVSB 1600 is only compatible with the 1600mAh Power Supply and COVSB 2600 is only compatibl...

Страница 43: ...mmendations Electrodes Ottobock Electrode 13E200 50 Yes Ottobock Electrode 13E200 60 Yes Ottobock Suction Socket Electrode 13E202 50 Yes Ottobock Suction Socket Electrode 13E202 60 Yes Steeper Electro...

Страница 44: ...COVVI website Steeper Espire Pro Elbow Please see COVVI website Steeper Espire Hybrid Elbow Please see COVVI website Steeper Espire Classic Elbow Please see COVVI website Steeper Espire Classic Plus...

Страница 45: ...Standard Wrist Rotator 5010045 Black Please see COVVI website Fillauer MC ProWrist Rotator 5010056 Black Please see COVVI website Pattern Recognition COAPT GEN2 BEMF AEMF Yes Must use Motion Control...

Страница 46: ...immunity of the COVVI Hand and result in improper operation WARNING Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer th...

Страница 47: ...a default setup combining the functionality of other prosthetic devices on the market for efficient interchangeability For new users as they become more familiar with their hand they can test out diff...

Страница 48: ...en use your email address and new password to log into the COVVI Go App on your phone or tablet The COVVI Web Portal operates on an invite only basis You need to add your patients for them to be able...

Страница 49: ...both the COVVI Hand and your device If Bluetooth isn t enabled on your device the App will notify you When you turn the COVVI Hand on Bluetooth is enabled for 60 seconds and then it turns off to save...

Страница 50: ...ck on Report a Bug and fill out the form which will be sent to us along with the hand s serial number so we can assist them Software Update is to perform the remote updates to the Firmware and Gatewar...

Страница 51: ...ation an additional threshold will appear on the Input Graph so you can determine the signal needed for Co contraction to be triggered Commonly prosthetic users have background noise also known as bas...

Страница 52: ...n and Max thresholds and offers high speed without the need for high magnitude signals but this setup can make it more challenging to get fine control of the hand at lower speeds The closer the On and...

Страница 53: ...of the graph The left set of bars represent Input A and the right set of bars represent Input B The inner set of bars closest to the graph have two circles saying ON and MAX slide the circles left or...

Страница 54: ...evice In the bars layout click on Input Gain at the top of the screen and the line underneath the two bars will change to have one circle that says GAIN Slide the circle to the right to amplify whiche...

Страница 55: ...izard screen you can leave without making any changes Changes are not made in real time all changes will be reflected once you complete all the stages in the Setup Wizard The first screen in the Setup...

Страница 56: ...close signal but this can be inverted if the electrodes are wired the other way around 11 0 COVVI Go App Linear Transducer These devices offer proportional control of myoelectric components for users...

Страница 57: ...ntained to activate a Long Hold Open grip switch trigger or release the signal and reapply another signal before the Direction Change Time so it is interpreted as another open signal to activate the O...

Страница 58: ...for daily activities for example one table for grips used at home another for grips used when at work If the hand is to be used with a COAPT system remove all grips from the tables except the primary...

Страница 59: ...showing the hand closing and opening in that grip To exit the video click on it Choose the desired grip and click on Done The grip will now appear in the next available position Grips can only be add...

Страница 60: ...ser Defined Grips at once Click on one of the spaces If it doesn t have a grip assigned you only need to click it once if it does have a grip already assigned you will need to double click it This wil...

Страница 61: ...Open An Open Open signal is an open signal to fully open the hand followed by another open signal The second open signal must be sent before the Open Open time Long Hold Open A Long Hold Open signal...

Страница 62: ...ned to switch to a non opposed grip the thumb will move to a non opposed position The hand must be fully open Thumb Tap Supinate at Non Opposed The thumb is tapped outwards but will remain in a non op...

Страница 63: ...evious grip in the table is selected Next Table The first grip in the next table is selected Previous Table The first grip in the previous table is selected Switch to Table A B C D The first grip in T...

Страница 64: ...ingers sense an object is starting to slip they reapply a small continuous force or pulse to gently grasp the object It monitors the grip every half a second Auto Relax After a certain period of inact...

Страница 65: ...reduced This is a feature designed to aid new users who are still adapting to using a prosthetic device Mode Specific Parameters Digit Hold Time This is the time you have to apply pressure on the FSR...

Страница 66: ...speed for just opening or just closing the hand This is a feature designed to aid new users who are still adapting to using a prosthetic device For Single Site Alternating the following parameters ca...

Страница 67: ...ore and after values of everything you are changing Click on Finish in the top right of the Changes screen and all changes will be saved and sent to the hand There is a prompt to save your configurati...

Страница 68: ...k on Advanced in the Config Overview screen There are five sections you can edit which follow the same order as the Setup Wizard Click on Edit to right of the section you would like to make a change t...

Страница 69: ...d to the internet to save a new config If you want to view a configuration click on View to the right of the name Another box will appear showing all the details of that configuration including the co...

Страница 70: ...t a Bug feature enables the user to report any issues they may experience with their COVVI Hand Click on Report a Bug and a form will appear for the user to fill out and submit to COVVI When submittin...

Страница 71: ...updates Do the Firmware update first then the Gateware update To perform the update click on it and a box will appear summarising the changes the update includes Click on Start Update The update first...

Страница 72: ...pp Clicking on Console will bring up a list of actions one of which is Reset Hand This feature allows you to reset the hand s configuration to the default configuration There is the option to choose o...

Страница 73: ...nded to service the COVVI Hand every year If the user notices any problems with their COVVI Hand please contact COVVI Customer Services so COVVI Ltd and COVVI USA INC can perform a service and assist...

Страница 74: ...claimed warranties Our obligation is limited only to the repair or replacement of defective parts within the warranty period or at the sole discretion of COVVI to refund the purchase price of a full r...

Страница 75: ...tation in those instances where changes alterations or modifications are made in materials at the request or instruction of the customer the customer agrees not to claim or commence suit against COVVI...

Страница 76: ...s that are covered and not covered under warranty Any product out of warranty that is sent in to COVVI will be evaluated by our Quality Department and quoted with repair parts and labour as required O...

Страница 77: ...tomer Services so COVVI Ltd and COVVI USA INC can perform a service and assist with any maintenance issues Clinicians will need to fill out a Repair Form and obtain a COVVI Repair Number Get in touch...

Страница 78: ...covvi com Unit 4 Quayside Business Park Leeds LS10 1DJ 020 3949 9500 16 0 Disposal Please check your local regulations prior to disposing any items to avoid having a detrimental impact on health and t...

Страница 79: ...llowing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation United States...

Страница 80: ...or on his behalf by a third party General Product Name COVVI Wrist Kit Legal Manufacturer Name on Label COVVI Ltd Unit 4 Direct House Quayside Business Park George Mann Road Leeds LS10 1DJ United Kin...

Страница 81: ...half by a third party General Product Name COVVI Power Supply Legal Manufacturer Name on Label COVVI Ltd Unit 4 Direct House Quayside Business Park George Mann Road Leeds LS10 1DJ United Kingdom Manuf...

Страница 82: ...half by a third party General Product Name COVVI Hand Legal Manufacturer Name on Label COVVI Ltd Unit 4 Direct House Quayside Business Park George Mann Road Leeds LS10 1DJ United Kingdom Manufacturers...

Страница 83: ...ect House Quayside Business Park Leeds LS10 1DJ Phone 44 0 20 3949 9500 Email customerservice covvi com Website www covvi com v1 3 3b July 2022 Advena Ltd Tower Business Centre 2nd Flr Tower Street Sw...

Отзывы: