CountyLine CLZS25T Скачать руководство пользователя страница 4

Risk of electric shock. Can shock, burn or 

kill. Pump should always be electrically grounded to a 

suitable electrical ground such as a grounded water pipe 

or a properly grounded metallic raceway, or ground wire 

system. Do not cut off round ground pin.

8.  If pump discharge line is exposed to sub-freezing 

weather conditions, portion of exposed pipe must 

be installed so any water remaining will drain out or 

down due to gravity. Failure to do this can cause water 

trapped in discharge to freeze which could result in 

damage to pump.

9.  After piping, check valve and float switch have been 

installed, the unit is ready for operation.

10.  Check the pump operation by filling sump with water 

and observing pump operation through one complete 

cycle. For switch settings see the Electrical and Switch 

Specifications chart on Page 2.

 Risk of flooding. Can cause personal injury 

and/or property damage. Failure to make this operational 

check may lead to improper operation, premature failure, 

and flooding.

Operation

Risk of electric shock. Can shock, burn or 

kill. Do not handle a pump or pump motor with wet 

hands or when standing on wet or damp surface, or in 

water.
1.  Shaft seal depends on water for lubrication. Do not 

operate pump unless it is submerged in water as seal 

may be damaged if allowed to run dry.

2.  Motor is equipped with automatic reset thermal 

protector. If temperature in motor should rise, switch 

will cut off all power before damage can be done 

to motor. When motor has cooled, switch will reset 

automatically and restart motor. If protector trips 

repeatedly, pump should be removed and checked. 

Low voltage, long extension cords, clogged impeller, 

very low head or lift, or a plugged or frozen discharge 

pipe, etc., could cause protector to trip.

3.  Pump will not remove all water. If operating a pump 

manually and suddenly no water comes out of the 

discharge hose, shut off the unit immediately. The unit 

has broken prime due to a very low water level.

Risk of electric shock. Can shock, burn or 

kill. Before attempting to check why unit has stopped 

operating, disconnect power from unit. 

Operation 4

4829 0205

6615 0712

Содержание CLZS25T

Страница 1: ...sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 800 535 4950 Espa ol Paginas 9 16 CLZS25T CLZS33T 2014 Pentair Ltd All Rights Reserved CL973 06 10 14 OWNER S MANUAL Submersibl...

Страница 2: ...tors at a safe distance from work area d Make workshop child proof with padlocks master switches and by removing starter keys 11 When wiring an electrically driven pump follow all electrical and safet...

Страница 3: ...tall an in line check valve or an in pump check valve to prevent flow backwards through pump when pump shuts off NOTICE If your check valve is not equipped with an air bleed hole to prevent airlocking...

Страница 4: ...tion premature failure and flooding Operation Risk of electric shock Can shock burn or kill Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water 1 Shaf...

Страница 5: ...Description Qty CLZS25T CLZS33T 1 Power Cord Assembly 1 PS117 54 TSU 2 Tethered Float Assembly 1 FP18 15BD 4 Screw 8 32 x 7 8 4 5 Motor 1 6 Upper Volute 1 P51 325 7 Screw 8 32 x 1 2 5 8 Impeller 1 Se...

Страница 6: ...switch Restricted discharge obstacle or ice in piping Remove pump and clean pump and piping Float obstructed Remove obstruction Restricted intake screen Remove the pump and clean the intake screen and...

Страница 7: ......

Страница 8: ...ommercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been rem...

Страница 9: ...que correspondan 12 Esta bomba solamente se puede usar con corriente de 115 voltios monof sica y est equipado con un cord n aprobado de 3 conductores y 3 clavijas del tipo de puesta a tierra Risque d...

Страница 10: ...de PTFE para roscas de tuber a Enrosque la tuber a en la bomba a mano y despu s apri tela 1 1 2 vueltas Risque d inondation Peut causer le mauvais fonctionnement ou une panne pr matur e de la pompe Si...

Страница 11: ...to impropio falla prematura e inundaci n Funcionamiento Risque de secousses lectriques Pouvant causer des br lures voire la mort No manipule la bomba o el motor de la bomba con las manos mojadas o cua...

Страница 12: ...PS1 325 Ref Descripci n Cant CLZS25T CLZS33T 1 Tornillo de abrazadera de cordon 1 PS117 54 TSU 2 Unidad del interruptor de flotador anclado 1 FP18 15BD 4 Tornillo 8 32 x 7 8 4 5 Motor 1 6 Voluta supe...

Страница 13: ...lado Reemplace el interruptor del flotante La bomba no se desconecta Interruptor defectuoso del flotante Reemplace el interruptor del flotante Descarga obstruida obst culos o hielo en las tuber as Ret...

Страница 14: ......

Страница 15: ...aciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de CountyLine Las bo...

Страница 16: ......

Отзывы: