Troubleshooting 6

 Risk of electric shock . Can shock, burn or kill. Unplug pump from power receptacle 

before working on pump.

Symptom

Possible Cause(s)

Corrective Action

Motor will not start 

or run

No electrical power

Check fuse, circuit breaker, power cord and electrical 

outlet.

Low line voltage

If voltage wiring under recommended minimum, 

check size of wiring from main source. If OK, contact 

Electric Company or local Hydro authority.

Faulty automatic switch

Operate switch manually and replace if inoperative.

Float or float rod stuck

Check to see float is not rubbing sump wall or float 

rod rubbing or stuck against sump cover.

Waterlogged float

Replace float if filled with water.

Motor overload tripped

If pump has been running and stops before sump 

is emptied, automatic overload may have tripped. 

Check inlet screen to be sure impeller is not jammed. 

If so, free impeller of obstruction.

Electrical malfunction

Check power cord, automatic switch and motor. 

Replace faulty parts as needed.

Motor runs but 

pump will not 

pump.

Inlet clogged

Check inlet and clean if needed.

Discharge line plugged

Clear discharge line and check valve for obstruction.

Low line voltage

Refer to Corrective Action on low line voltage above.

Pump airlocked

Drill a 1/8” (3.2mm) hole in discharge pipe just 

above pump body but below the check valve.

Broken impeller or shaft

Replace impeller or shaft as needed.

Pump starts and 

stops too often.

Improper positioning of float 

rod stop.

Lower float rod stop.

Faulty automatic switch.

Replace automatic switch.

Pump is noisy

Improper installation

Refer to Installation.

Noisy motor

Replace pump.

Pump will not stop 

running.

Debris around float or float 

rod stuck.

Remove debris from sump. Check to see float is 

not rubbing sump wall or float rod rubbing or stuck 

against sump cover.

Faulty automatic switch

Replace switch.

Motor defective

Replace pump.

Содержание CL3P

Страница 1: ...For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 7 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento...

Страница 2: ...1620 6 131 0 0 1 Know the pump application limitations and potential hazards Risk of fire and explosion Can cause severe injury property damage or death Do not use in explosive atmospheres Pump water...

Страница 3: ...rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed carr...

Страница 4: ...of electric shock Can shock burn or kill If your basement has water or moisture on floor do not walk on wet area until all power has been turned off If shut off box is in basement call electric compa...

Страница 5: ...y gravity Failure to do this can cause water trapped in discharge to freeze which could result in damage to pump 12 Install an in line check valve part number FP0026 10 to prevent flow backwards throu...

Страница 6: ...impeller is not jammed If so free impeller of obstruction Electrical malfunction Check power cord automatic switch and motor Replace faulty parts as needed Motor runs but pump will not pump Inlet clog...

Страница 7: ...25P 4 Impeller 1 PS5 269P 5 Base Plate 1 PS4 17P 6 Screws Base Plate 8 U30 934ZP 7 Float Rod Guide 1 RP0005249 8 Screw Guide Rod 1 U30 929ZP 9 Screw Base 1 SC004 116 10 Float 1 FT0013 63 11 Float Rod...

Страница 8: ...losi n Puede causar lesiones graves da os materiales o muerte No utilice la bomba en atm sferas explosivas Utilice esta bomba para bombear agua solamente Ignorar esta advertencia puede ocasionar da os...

Страница 9: ...roductos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al...

Страница 10: ...idad Si la caja el ctrica est en el s tano llame a la compa a el ctrica para que corte la electricidad de la casa o llame al departamento de bomberos para solicitar instrucciones Retire la bomba y rep...

Страница 11: ...n puede ocasionar el congelamiento del agua atrapada en la tuber a de descarga lo cual puede a su vez da ar la bomba 12 Instale una v lvula de control interna modelo FP0026 10 para impedir el retroce...

Страница 12: ...l impulsor de obstrucciones Defecto el ctrico Inspeccione el cable de alimentaci n el interruptor autom tico y el motor Reemplace las partes defectuosas seg n sea necesario El motor funciona pero la b...

Страница 13: ...de base 8 U30 934ZP 7 Gu a de la varilla de flotaci n 1 RP0005249 8 Tornillo Varilla de flotaci n 1 U30 929ZP 9 Tornillo Base 1 SC004 116 10 Flotador 1 FT0013 63 11 Varilla de flotaci n 1 RP005168S 1...

Страница 14: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 15: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 16: ......

Отзывы: