‘click position’ or for low burning to the fully closed position.

When the fire is burning normally the air control gives enough 
airwash to keep the glass clean. However, it will not always be 
possible to keep the glass clean with the air control fully closed. 

Keep the firebox well filled but do not allow fuel to spill over the top 
of the fuel retainer.

Logs should be evenly distributed, filling the firebed to give the most 
pleasing flame pattern. The air control must be fully opened after 
refuelling until the flames are established above the fire. It is best to 
refuel on to a hot bed of embers. If at this point the fire starts to die, 
the door must be cracked open until the fire is revived. If the fire has 
started to die down before refuelling, then more kindling wood must 
be added, the air control opened fully and the door cracked open to 
re-establish the firebed 

before

 adding larger logs (see suitable log 

sizes in Fuel section). This will avoid excessive smoke emission.

Care should be taken, especially when burning wood, that fuel does 
not project over the fuel retainer or damage to the glass may be 
caused when the door is closed. It can also cause the glass to blacken 
up. Maximum filling height is such that logs cannot fall from the fire 
when the door is opened.

For 

correct firing we recommend the use of a stove pipe thermometer 
which may be purchased from your supplier or from Charnwood.

Maximum filling height is such that logs cannot fall from the fire when 
the door is opened. In smoke controlled areas do not fill then stove 
above the level of the air holes in the back bricks, as overloading can 
cause excess smoke.

Do not operate with the door left open except as directed by the 
instructions as this can cause excessive smoke.

For optimum wood burning, it is important to leave a layer of ash 
around 1cm thick on the base of the stove. Before removing ash 
ensure that it has cooled down, scoop out the remaining ash and 
empty into a metal container. Please avoid emptying hot ash into 
plastic liners or bins.

To make ash removal easier there are scoops and ash carriers 
available. These may be purchased from your supplier or, in case of 
difficulty, from Charnwood. 

If an Optional Wood Ash Removal Grate is fitted, the Ashpan should 

REFUELLING

ASH CLEARANCE

be emptied regularly before it becomes too full. Never allow the ash 
to accumulate in the ashpan so that it comes in contact with the 
underside of the grate as this will seriously damage the grate bars. 

The ashpan is handled using the Door Opening tool and gloves 
provided. Ensure that the tool is fully engaged before lifting (See 
Fig.4). When carrying the ashpan, it should be kept horizontal and 
supported by the carrying handle to prevent it falling off the tool. 

REDUCED BURNING

MAINTENANCE

For reduced burning the fire door must be closed.

When burning wood in areas that are not smoke controlled, load 
some large logs on the fire and allow to burn for half an hour before 
closing the air control (this will help to reduce tar deposits in the 
chimney). Some experimentation may be necessary to find the setting 
most suitable for the type of fuel being used and the draw on the 
chimney.

Cleaning

Cleaning  the  Glass

The stove is finished with a high temperature paint which will 
withstand the temperatures encountered in normal use. This may be 
cleaned with a damp lint-free cloth when the stove is cold. Should re-
painting become necessary, high temperature paints are available 
from your supplier or from stove shops.

Most deposits on the glass may be burnt off simply by running the fire 
at a fast rate for a few minutes. If it becomes necessary to clean the 
glass then open the door and allow it to cool. Clean the glass using a 
damp cloth and then wiping over with a dry cloth. Any stubborn 
deposits on the glass may be removed with a proprietary stove glass 
cleaner or ceramic hob cleaner. Do not use abrasive cleaners or pads 
as these can scratch the surface which will weaken the glass and cause 
premature failure

7

®

OPERATING  INSTRUCTIONS

Fig.4.Ash Removal

Ashpan

Ashpan Tool

Extra carrying handle. 

Use with glove

Ashpan Tool

Содержание bembridge

Страница 1: ...Operating Installation Instructions ...

Страница 2: ......

Страница 3: ...m 9 If you need further help 9 INSTALLATION INSTRUCTIONS Health Safety Precautions CO Alarms Specification Chimney Hearth Fire Surround 11 Connection to Flues 12 Soot Doors 12 Pre Lighting Check 12 Commissioning 12 15 Fitting The Wood Ash Removal Grate 5 Riddling 6 Controlling The Fire Unpacking The Stove 10 10 10 10 10 Clean Air Act Information 12 13 Certification 14 Dimensions Parts List 16 Ref ...

Страница 4: ...eaner Any stubborn deposits on the glass may be Throat plate Take down once a month and clean Sweep sooty deposits into fire Chimney Have chimney swept twice a year Chimney can be swept through stove Servicing Stove should be serviced by a professional at least once a year p7 MAINTENANCE AND CLEANING Low Output High Output Boost Air control p5 Throat plate Improves efficiency of stove by slowing d...

Страница 5: ... these instructions before using the stove FUEL Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly and that the chimney has been swept is sound and free from any obstructions The stove is not suitable for use in a shared flue system Remember that the stove will be hot and that it is made from hard m...

Страница 6: ...d kindling in the firebox and cover with a few small dry logs Open the air control fully see Fig 3 Light the paper or fire lighters The door may be left cracked open for a few minutes to assist the combustion and heat up the firebox more quickly When the kindling wood is well alight add a few more small logs close the door but leave the air control fully open When the flames are established around...

Страница 7: ... a metal container Please avoid emptying hot ash into plastic liners or bins To make ash removal easier there are scoops and ash carriers available These may be purchased from your supplier or in case of difficulty from Charnwood If an Optional Wood Ash Removal Grate is fitted the Ashpan should REFUELLING ASH CLEARANCE be emptied regularly before it becomes too full Never allow the ash to accumula...

Страница 8: ...f sweep s brushes are available to suit different flueways For prefabricated insulated chimneys the manufacturers instructions with regard to sweeping should be consulted When Not in Use If the fire is going to be out of use for a long period for instance in the summer then to prevent condensation and hence corrosion the air control should be left fully open and the fire door left ajar It Is also ...

Страница 9: ...he following immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely dispose of the fuel from the appliance c Check for flue or chimney blockage and clean if required d Do not attempt to re light the fire until cause of fuming has been identified if necessary seek professional advice The most common cause of fume em...

Страница 10: ...ir permeability of the house In older properties the air permeability will be above 5 0m h m but in some modern properties it may be less 10 INSTALLATION INSTRUCTIONS use in a shared flue system In addition to these instructions the requirements of BS 8303 and BSEN 15287 1 2007 must be fulfilled Local Authority Bylaws and Building Regulations including those referring to national and European Stan...

Страница 11: ...in thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state that the hearth must extend in front of the stove by at least 225mm 9 in and to the sides of the stove by at least 150mm 6 in If in doubt as to the positioning of the stove expert advice should be sought either from the supplier or the local ...

Страница 12: ...liance but in most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept The optional vertical rear flue connector does allow the chimney to be swept through the stove Soot doors may either be in the actual brickwork of the chimney or in the register plate Various positions of soot doors are shown in Figs 6 to 9 Ensure that the throat plate is fitted ...

Страница 13: ...nt that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The Charnwood Bembridge has been recommended as suitable for use in smoke control areas when burn...

Страница 14: ...o AT044 CPD 2015 Fuel type WOOD LOGS Emission of CO in combustion products 0 06 Mean flue gas temperature 247 C Space heating thermal output 5 0kW Energy efficiency 82 Minimum distance to combustible materials Side Rear With heat shield and HT insulated flue connector 25mm insulation Side Rear 500mm 400mm 500mm 175mm Particles mg m 30 Fulfilled requirements BStV of the City of Munich and the City ...

Страница 15: ...RIDGE 15 Front Side Rear 292 144 292 455 485 560 611 430 398 153 114 82 130 Plan View Optional Vertical Rear Flue Adapter Store Stand Standard Model 250 0 643 485 185 455 745 796 458 62 79 76 140 i d to suit 125mm 5 flue pipe 0 520 ...

Страница 16: ...ate Support 21 002 BR020 Hinge Casting 52 010 NR042 R H Grate Support 22 008 BW39 S Hinge Pin Set 5mm x 25mm 53 010 NR061 Rear Grate Support 23 008 FFW026 M6 Heay Brass Washer 54 002 EY03 Grate Plate 24 002 AT001 A Door Assembly 55 010 DR060 Riddler Rod 25 010 AT016 Latch Bracket 56 002 PX89 Riddler Knob 26 002 PX92 Door Knob Spindle 57 010 PV33 Vertical Rear Flue Adaptor Opt l Extra 27 008 FFN001...

Страница 17: ......

Страница 18: ......

Страница 19: ... e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r ...

Отзывы: