background image

OPTIONAL WOOD ASH REMOVAL GRATE

Wood can be burnt on the base. There is an optional wood ash 
removal grate available for ash clearance only. 

Tools required for fitting the wood ash removal grate:

10mm Spanner

Pozidriv screwdriver

Before fitting the wood ash removal grate (Fig. 1) remove the fuel 
retainer and the wood ash retainer. The wood ash retainer is not 
required when the wood ash removal grate is fitted.

Undo the nut on the blanking hole using a 10mm spanner. Remove 
the cover and spacing washer (ensure you keep these in a safe place 
as you will need to replace them if the riddling grate is removed).

Feed the riddler rod through the hole on the right hand side of the 
stove, and slide one washer onto the rod (if there is not sufficient 
room to the right of the stove to do this then remove the riddler 
knob, fit one washer over the rod and then slide the rod through the 
hole from the inside of the stove). 

Feed the rod through the two side fireplates and slide the other 
washer on to the rod so that the washers end up outside the two side 
fireplates. With the side fireplates pushed together fit the retaining 
clips so that the washers come inside the clips. 

Slide the side fireplates apart so that they rest against the sides of the 
firebox. Slot in the front and rear support plates.

Fit the grate plates into position through the front and rear grate 
support plates, making sure they locate correctly onto the riddler 
rod. Fit the fuel retainer. Slide the ashpan under the grate.

Congratulations on becoming the owner of a Charnwood Bembridge 
Stove. Your stove has been approved in smoke control areas to burn 
wood logs if it is used in accordance with these instructions. It is very 
important that you read and understand these instructions before 
using the stove. 

FUEL

Before lighting the stove check with the installer that the work and 
checks described in the Installation Instructions have been carried out 
correctly and that the chimney has been swept, is sound and free 
from any obstructions. The stove is not suitable for use in a shared 
flue system.

Remember that the stove will be hot and that it is made from hard 
materials – ensure that you have good balance before operating the 
fire. Always use the provided operating tool and gloves.

Do not use an aerosol spray on or near the stove when it is alight. 
There is a risk of explosion or flash ignition of the spray.

 

The stove is suitable for intermittent operation.

This stove has been designated to burn wood. Only dry well seasoned 
wood should be burnt on this appliance as burning wet unseasoned 
wood will give rise to heavy tar deposits in the stove, on the glass and 
within the chimney. For the same reason hard woods (such as Ash, 
Beech and Oak) are better than soft woods (such as Pine and 
Spruce). Burning wet unseasoned wood will also result in 
considerably reduced outputs. The wood should be cut and split and 
then left to season in a well ventilated dry place for at least one year 
but preferably two years before use. Approximate suitable log sizes 
are:

305mm(12in) long and 75mm (3in) diameter

PETROLEUM COKE IS NOT SUITABLE FOR USE ON 

THIS APPLIANCE. ITS USE WILL INVALIDATE THE 

GUARANTEE.

This stove is not designed to burn household waste.

For advice on other fuels please contact Charnwood.

When using the stove in situations where children, aged and/or 
infirm persons are present a fireguard must be used to prevent 
accidental contact with the stove. The fireguard should be 
manufactured in accordance with BS 8423:2002.

®

OPERATING  INSTRUCTIONS

5

Fig.1. Wood Ash Removal Grate

Grate Plates

Front Grate Support

RH Side Grate Support

Ashpan

Riddler Rod

Rear Grate Support

LH Side Grate Support

Содержание bembridge

Страница 1: ...Operating Installation Instructions ...

Страница 2: ......

Страница 3: ...m 9 If you need further help 9 INSTALLATION INSTRUCTIONS Health Safety Precautions CO Alarms Specification Chimney Hearth Fire Surround 11 Connection to Flues 12 Soot Doors 12 Pre Lighting Check 12 Commissioning 12 15 Fitting The Wood Ash Removal Grate 5 Riddling 6 Controlling The Fire Unpacking The Stove 10 10 10 10 10 Clean Air Act Information 12 13 Certification 14 Dimensions Parts List 16 Ref ...

Страница 4: ...eaner Any stubborn deposits on the glass may be Throat plate Take down once a month and clean Sweep sooty deposits into fire Chimney Have chimney swept twice a year Chimney can be swept through stove Servicing Stove should be serviced by a professional at least once a year p7 MAINTENANCE AND CLEANING Low Output High Output Boost Air control p5 Throat plate Improves efficiency of stove by slowing d...

Страница 5: ... these instructions before using the stove FUEL Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly and that the chimney has been swept is sound and free from any obstructions The stove is not suitable for use in a shared flue system Remember that the stove will be hot and that it is made from hard m...

Страница 6: ...d kindling in the firebox and cover with a few small dry logs Open the air control fully see Fig 3 Light the paper or fire lighters The door may be left cracked open for a few minutes to assist the combustion and heat up the firebox more quickly When the kindling wood is well alight add a few more small logs close the door but leave the air control fully open When the flames are established around...

Страница 7: ... a metal container Please avoid emptying hot ash into plastic liners or bins To make ash removal easier there are scoops and ash carriers available These may be purchased from your supplier or in case of difficulty from Charnwood If an Optional Wood Ash Removal Grate is fitted the Ashpan should REFUELLING ASH CLEARANCE be emptied regularly before it becomes too full Never allow the ash to accumula...

Страница 8: ...f sweep s brushes are available to suit different flueways For prefabricated insulated chimneys the manufacturers instructions with regard to sweeping should be consulted When Not in Use If the fire is going to be out of use for a long period for instance in the summer then to prevent condensation and hence corrosion the air control should be left fully open and the fire door left ajar It Is also ...

Страница 9: ...he following immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely dispose of the fuel from the appliance c Check for flue or chimney blockage and clean if required d Do not attempt to re light the fire until cause of fuming has been identified if necessary seek professional advice The most common cause of fume em...

Страница 10: ...ir permeability of the house In older properties the air permeability will be above 5 0m h m but in some modern properties it may be less 10 INSTALLATION INSTRUCTIONS use in a shared flue system In addition to these instructions the requirements of BS 8303 and BSEN 15287 1 2007 must be fulfilled Local Authority Bylaws and Building Regulations including those referring to national and European Stan...

Страница 11: ...in thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state that the hearth must extend in front of the stove by at least 225mm 9 in and to the sides of the stove by at least 150mm 6 in If in doubt as to the positioning of the stove expert advice should be sought either from the supplier or the local ...

Страница 12: ...liance but in most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept The optional vertical rear flue connector does allow the chimney to be swept through the stove Soot doors may either be in the actual brickwork of the chimney or in the register plate Various positions of soot doors are shown in Figs 6 to 9 Ensure that the throat plate is fitted ...

Страница 13: ...nt that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The Charnwood Bembridge has been recommended as suitable for use in smoke control areas when burn...

Страница 14: ...o AT044 CPD 2015 Fuel type WOOD LOGS Emission of CO in combustion products 0 06 Mean flue gas temperature 247 C Space heating thermal output 5 0kW Energy efficiency 82 Minimum distance to combustible materials Side Rear With heat shield and HT insulated flue connector 25mm insulation Side Rear 500mm 400mm 500mm 175mm Particles mg m 30 Fulfilled requirements BStV of the City of Munich and the City ...

Страница 15: ...RIDGE 15 Front Side Rear 292 144 292 455 485 560 611 430 398 153 114 82 130 Plan View Optional Vertical Rear Flue Adapter Store Stand Standard Model 250 0 643 485 185 455 745 796 458 62 79 76 140 i d to suit 125mm 5 flue pipe 0 520 ...

Страница 16: ...ate Support 21 002 BR020 Hinge Casting 52 010 NR042 R H Grate Support 22 008 BW39 S Hinge Pin Set 5mm x 25mm 53 010 NR061 Rear Grate Support 23 008 FFW026 M6 Heay Brass Washer 54 002 EY03 Grate Plate 24 002 AT001 A Door Assembly 55 010 DR060 Riddler Rod 25 010 AT016 Latch Bracket 56 002 PX89 Riddler Knob 26 002 PX92 Door Knob Spindle 57 010 PV33 Vertical Rear Flue Adaptor Opt l Extra 27 008 FFN001...

Страница 17: ......

Страница 18: ......

Страница 19: ... e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r ...

Отзывы: