background image

COUNTERFOG® PILAR 

 

User Manual

 

COUNTERFOG® EBT de la UAH S.L.  

 

24 

 

11.

 

WARRANTY 

 

COUNTERFOG  EBT  de  la  UAH  S.L

  warrants  that  the  Products  meet  the  above 

specifications  and  will  be  delivered  free  of  defects  with  respect  to  materials  and 
workmanship 

- Excluded from this warranty are parts that are subject to natural wear & tear as well 
as consumable parts (e.g., air filter, water filter, hoses, and valves). 

- The warranty for Products will be extinguished after two (2) years from the date of 
shipment.  With  respect  to  elements  subject  to  mechanical  wear,  such  as,  but  not 
limited to, bonds, pipes or other similar elements (6) months. Once these deadlines 
have elapsed, no claims or refunds of any kind will be accepted for this reason.  

If the Products do not comply with the foregoing warranties, COUNTERFOG shall, at its 
option,  repair  or  replace  the  defective  Products,  provided  that  Buyer  notifies 
COUNTERFOG in writing, prior to the end of the warranty period, and within fifteen 
(15) days of the discovery of the anomaly or defect. The repair, replacement or new 
warranty  service  by  COUNTERFOG  shall  not  extend  or  renew  the  corresponding 
warranty period. 

-  Buyer  shall  obtain  COUNTERFOG's  approval  of  the  specifications  of  any  tests  it 
intends  to  conduct  to  determine  whether  there  is  a  non-conformity.  COUNTERFOG 
may,  in  any  case  and  in  advance,  check  defects  caused  by  the  means  it  deems 
appropriate, without  the  Purchaser being able to hinder  the actions of the persons 
designated by COUNTERFOG to verify such non-conformity. 

- COUNTERFOG shall not accept, for a period longer than six (6) months, those Used 
Products owned by the Purchaser, which at the latter's will have been deposited in 
COUNTERFOG's  premises.  After  the  last  period,  COUNTERFOG  shall  be  entitled  to 
dispose of them at his option. 

- This warranty is available to the original purchasers only and cannot be transferred 
or assigned. If during the warranty period a default on the device should be noted, 
please  proceed  as  follows:  (i)  Call  COUNTERFOG  EBT  de  la  UAH  S.L  (ii)  Prepare  the 
shipment of the device back to COUNTERFOG EBT de la UAH S.L and the original invoice 
.Please note that the device should be packed in the original shipping box. Should this 
not be the case the device will not qualify for the above explained warranty service 

and will be repaired or replaced at customers’ expenses. COUNTERFOG EBT

 de la UAH 

S.L will not absorb shipping costs associated with the returns. 

-  The  Warranty  shall  not  cover  (a)  any  defects  and/or  malfunctions  caused  by  the 
storage, installation, commissioning, use, or maintenance performed by the Purchaser 
or  third  parties  (b)  any  defects and/or malfunctions caused  by  amphibians,  insects, 
rodents,  birds  and/or  mammals  (c)  those  defects  and/or  malfunctions  caused  by 
obstructions  not  attributable  to  a  manufacturing  defect  (d)  those  defects  and/or 
malfunctions caused by incoming water or other added elements that do not comply  
with the physical/chemical and/or biological parameters recommended upon and/or 

Содержание PILAR

Страница 1: ...COUNTERFOG IS A REGISTERED TRADEMARK OF COUNTERFOG EBT DE LA UAH S L IT IS STRICTLY PROHIBITED TO DISTRIBUTE COPY AND OR MODIFY THIS DOCUMENT COUNTERFOG PILAR USER MANUAL SEPTEMBER 2021...

Страница 2: ...or no definido 3 1 TECHNICAL DATA Error Marcador no definido 3 2 COMPONENTS 7 4 RECOMMENDED PERSONAL PROTECTION EQUIPMENT PPE 11 5 ROOM PREPARATION 11 6 OPERATING INSTRUCTIONS 12 6 1 POSITION 12 6 2 F...

Страница 3: ...ects It provides a dynamic fog cone composed of sub micrometric droplets of liquid which when projected into the air catch air borne matter dust aerosols spores etc Applying the cone with biocidal liq...

Страница 4: ...ehicles goods or objects Risk of Damage Breathing fogs or mists of chemical substances or disinfectants may be toxic Contact of chemical substances or disinfectants with skin mouth or mucous must be a...

Страница 5: ...mixing liquids if manufacturers do not recommend it Be sure that the nozzle hose and pipes of the Counterfog PILAR are empty and clean before filling the container with liquid Use only authorized liq...

Страница 6: ...le disinfectant is being fogged Stay out of the room after treatment until room re entry wait time has expired Keep door and windows closed Re entry before the wait time has expired could result in se...

Страница 7: ...COUNTERFOG PILAR User Manual COUNTERFOG EBT de la UAH S L 7 2 1 COMPONENTS Part Name 1 Compressor 2 Pressure tank 3 FILL Filling valve 4 EMPTY Drain valve 5 Filter...

Страница 8: ...l COUNTERFOG EBT de la UAH S L 8 6 LIQUID Liquid valve 7 AIR Air valve 8 Check valve 9 Safety valve 10 Pressure gauge 11 VENT Vent valve 12 Filling 13 Coaxial hose 14 Counterfog F1 6 Nozzle for massiv...

Страница 9: ...COUNTERFOG PILAR User Manual COUNTERFOG EBT de la UAH S L 9...

Страница 10: ...COUNTERFOG PILAR User Manual COUNTERFOG EBT de la UAH S L 10...

Страница 11: ...disinfection remove bed covers Clothes and objects that should be disinfected separately Depending on the disinfectant to be used evacuation of any person with no Personal Protection Equipment will be...

Страница 12: ...point 2 2 LIQUIDS SUITABLE TO BE FOGGED and ANNEX 1 to verify the disinfectants authorized in Spain o Unplug the equipment from the electrical line o Double check that all elements are well tight and...

Страница 13: ...Close 3 FILL o Screw the cap to the funnel screw 12 o Close and lock the vent valve Close 11 VENT 5 3 POWER CONNECTION Before making electrical connections carefully check that the voltage supplied i...

Страница 14: ...11 bar Counterfog PILAR is programmed to automatically provide a pressure of 11 bar Check pressure gauge check 10 5 5 OPERATION Double check all valves 3 FILL 4 EMPTY 6 LIQUID 7 AIR and 11 VENT are c...

Страница 15: ...INFECTION Counterfog PILAR disinfects both air and surfaces For an effective operation the user must gently aim corners from one side to the other from the upper to the lower parts The fog cone must b...

Страница 16: ...hold 14 pointing at the floor Open the air valve Open 7 AIR Open the liquid supply valve Open 6 LIQUID Proceed to disinfection 8 END OF OPERATION When wanted to finish disinfection follow in order the...

Страница 17: ...VENT are closed o Carefully release and open the vent valve Open 11 VENT Wait until pressure in the tank becomes the atmospheric no air flows out at that time o To evacuate the remaining liquid from...

Страница 18: ...he 120 V 60 Hz supply line o Activate the switch on the left Activate switch 1 yellow arrow in the figure which activates the fan o Activate the switch on the right Activate switch 2 green arrow in th...

Страница 19: ...all elements are well tight and there are no mechanical damages or bumps The tank may be pressurized o Check all valves 3 FILL 4 EMPTY 6 LIQUID 7 AIR and 11 VENT are closed o The two switches at the t...

Страница 20: ...acuated Always wear gloves and safety glasses when evacuating the residual liquid from the device o When finish evacuating liquid close valve 4 close 4 EMPTY o Screw the cap to the funnel screw 12 o O...

Страница 21: ...the compressor o Deactivate the switch on the left deactivate switch 1 yellow arrow in the figure which deactivates the fan Please follow the steps in the correct order Counterfog PILAR can be then un...

Страница 22: ...t liquid Electric shock hazard Do not plug in if electrical plug or parts are wet While in use the bottom of the device may become warm to the touch Be careful Use Personal Protection Equipment PPE in...

Страница 23: ...ng Device was tipped on its side without completely empty Switch off and unplug device open device and remove water Let device completely dry If device still leaks call technical service Device leaks...

Страница 24: ...urchaser being able to hinder the actions of the persons designated by COUNTERFOG to verify such non conformity COUNTERFOG shall not accept for a period longer than six 6 months those Used Products ow...

Страница 25: ...vironments or purposes in which there are no adequate factors conditions or characteristics to obtain optimal performance of the Product k normal wear and tear of the Products l those losses and or da...

Страница 26: ...tate authority or Buyer or Buyer s contractors or suppliers COUNTERFOG s total liability for all claims of any class arising out of or relating to the conclusion performance or breach of the Contract...

Страница 27: ...protect the environment to prevent environmental pollution and to improve the recycling of raw materials a directive was issued by the European Commission which states that all electrical and electron...

Страница 28: ...re the viricide products authorized and registered in Spain that have proven effective against viruses in accordance with the UNE EN 14476 standard Antiseptics and chemical disinfectants Quantitative...

Страница 29: ...C SF x x x TOTAL SHOCK SF x x x TERMINAL FORTE SR x x x BIOQUELL HPV AQ x x x Vaprox Hydrogen Peroxide Sterilant x x Vaprox 59 Hydrogen Peroxide Sterilant x x DUROX LRD x x x DYBAC NT2G x x x x WA 520...

Страница 30: ...alt 49 7 10 49 oxygen available Specialized professional staff 10 gr product 1 l of water for 50 75 m Air disinfection Fogging with the product diluted in water Recommended safety period 12 hours OX V...

Страница 31: ...ces and fabrics by conventional spraying of the product from a distance of about 25 cm Aerial disinfection for use by specialized personnel aerial spraying of the product OX VIRIN READY TO USE 15 20 4...

Страница 32: ...in Safety period of 24 hours AMBIDOX 25 19 20 40 90 10190 Didecyldimethyl ammonium chloride 6 93 Professional staff Consult with the manufacturer depending on the characteristics and requirements of e...

Страница 33: ...ersion wiping or mopping with the product diluted in water respecting the contact times Disinfection of air conditioning equipment and ducts In air conditioning equipment the instructions for use will...

Страница 34: ...ple Safety period of 24 hours Disinfection of air conditioning equipment and ducts In air conditioning equipment the mode of use will be only in a timely manner with subsequent recycling of clean air...

Страница 35: ...re product with automated vaporization system European registration of products for surface and airborne disinfection environmental use Commercial name Registration number Active substance User Manufa...

Страница 36: ...in contact with food feed food industry Commercial name Registration Number Active Substance User Manufacturer s recommended concentration Manufacturer s recommended application procedure RELY ON VIR...

Страница 37: ...l with subsequent recycling of clean air for at least 1 hour in the absence of people after which the 24 hour safety period will be respected It must not be used continuously by mechanical application...

Страница 38: ...ended safety period 24 hours SANITAS PROCSAN 17 20 40 90 05489 HA Didecyldimethyl ammonium chloride 6 9 Professional staff 2 at the rate of 300 ml m2 Contact disinfection surfaces and equipment by spr...

Страница 39: ...pure product or diluted in water DYBAC NT2G 15 20 40 07290 HA Glioxal 6 Glutaraldehyde 12 Specialized professional staff 2 at the rate of 0 3 0 5 l 100 m3 Contact disinfection surfaces and equipment...

Страница 40: ...anol 2 1 N 3 aminopropyl Ndodecylpropane 1 3 diamine 0 1 Professional staff Undiluted or diluted to 80 Contact disinfection Surfaces and equipment by spraying and immersing with the pure product or di...

Страница 41: ...use Surfaces and equipment by spraying scrubbing brushing wiping or immersing with the pure product Contact time 30 min Safety period of 24 hours AMBIDOX 25 19 20 40 90 1019 HA Didecyldimethyl ammoniu...

Страница 42: ...Didecyldimethyl ammonium chloride 6 93 Professional staff Consult with the manufacturer depending on the characteristics and requirements of each installation roughly 5 10 ml m3 Contact disinfection...

Страница 43: ...ucts In air conditioning equipment use will be only punctual with subsequent recycling of clean air for at least 1 hour in the absence of people after which the 24 hour safety period will be respected...

Страница 44: ...PROX 550 DES Hydrogen peroxide 35 Professional staff Undiluted Air disinfection apply the pure product with an automated vaporization system On the other hand considering the need for these biocide pr...

Страница 45: ...e 2 General public Undiluted Contact disinfection Surfaces by spraying with the pure product NDP AIR TOTAL GREEN 17 20 40 05645 Didecyldimethyl ammonium chloride 0 46 2 phenoxyethanol 0 1 Specialized...

Страница 46: ...mber Active Substance User Manufacturer s recommended concentration Manufacturer s recommended application procedure SANYTOL MULTI PURPOSE CLEANER 12 20 40 05237 Didecyldimethyl ammonium chloride 0 5...

Отзывы: