COUNTERFOG® PILAR
User Manual
COUNTERFOG® EBT de la UAH S.L.
34
Commercial name
Registration
Number
Active Substance
User
Manufacturer's
recommended
concentration
Manufacturer's recommended application
procedure
absence of people, after which the 24-hour
safety period will be respected. It must not be
used continuously by mechanical application
with a distributor.
TOTAL SHOCK SF
12-20/40/90-
02102
Glutaraldehyde: 2.5%
Specialized
professional
staff.
Undiluted at the
rate of 12 min/100
m
3
•
Contact disinfection: surfaces and
equipment by fogging with the pure product
Apply in absence of people. Safety period of
24 hours
•
Disinfection of air conditioning equipment
and ducts. In air conditioning equipment the
mode of use will be only in a timely manner
with subsequent recycling of clean air for at
least 1 hour without people, then comply
with the safety period of 24 hours. It should
not be used continuously by mechanical
application with a dispenser.
TERMINAL FORTE
SR
17-20/40/90-
05739
Hydrogen peroxide: 9%,
Peracetic acid: 0.25%,
Isopropyl alcohol:9.99%
- Specialized
professional
staff.
Undiluted at the
rate of 36 min/100
m
3
•
Contact disinfection: surfaces and
equipment by fogging with the pure product
Apply in absence of people. Safety period of
24 hours
•
Disinfection of air conditioning equipment
and ducts. Micronebulization with the pure
product, the mode of use will be only of