COUNTERFOG® PILAR
User Manual
COUNTERFOG® EBT de la UAH S.L.
12
Remove mattresses from beds and tilt them on their sides.
Assure all personnel have evacuated the room before fogging.
Remove plants, animals, beverages and food.
Close windows and doors of the room.
All entrances to the treatment room must be placarded. Placards must be placed in
advance of the treatment in order to keep unauthorized persons from entering the room
5.
OPERATING INSTRUCTIONS
5.1
POSITION
Place device on a stable, flat, dust-free, not slippery, horizontal surface which can
appropriately support its weight.
5.2
FILLING
Counterfog® PILAR
must be used only with approved disinfectants. Please refer
to point 2.2 LIQUIDS SUITABLE TO BE FOGGED and ANNEX 1 to verify the
disinfectants authorized in Spain.
o
Unplug the equipment
from the electrical line
o
Double check that all elements are well tight and there are no
mechanical damages or bumps.
The tank may be pressurized
o
Check
all valves (
3 “FILL”, 4 “EMPTY”
,
6 “LIQUID”
,
7 “AIR” and 11
“VENT”
) are
closed
.
o
The
two switches
at the top of
Counterfog® PILAR
must be
OFF
.
o
Carefully open the vent valve (
Open 11
“VENT”
).
o
Wait until pressure in the tank is the atmospheric (no air flows out at
that time).
o
Open the filling valve (
Open 3
“FILL”
) and
double check that valve 4
“EMPTY”
is closed
.
o
Carefully unscrew the cap from the funnel (
unscrew 12
) and leave the
cap in a suitable place.
o
Pour the liquid into the funnel following the manufacturer's
recommendations. Make sure that the amount poured is always less
than 3.9 liters [1.09 gallons (US)].