Wait for 12 minutes
to remove the moisture of the pressure tank.
o
Deactivate the switch on the right (
deactivate switch 2
) (
green arrow in the
figure
) which deactivates the compressor.
o
Deactivate the switch on the left (
deactivate switch 1
)
(yellow arrow in the
figure
) which deactivates the fan.
Please, follow the steps in the correct order
Counterfog® PILAR can be then unplugged, moved to another room and plugged
again.
o
Unplug the equipment
from the 120 V/60 Hz supply line.
o
Close all valves
(3 “FILL”, 4 “EMPTY”, 6 “LIQUID”, 7 “AIR” and 11 “VENT”
closed).
o
Unplug the equipment
from the 120 V/60 Hz supply line.