When finish evacuating liquid, close valve 4 (
close 4 “EMPTY”
).
If any type of disinfectant has been used, please go to next indication. Otherwise,
follow the next procedure to dry the tank. Remember that a correct maintenance
lengthen the durability of the product.
o
Open the filling valve (
Open 3 “FILL”
), open the empty valve (
OPEN 4
“EMPTY”)
and open the vent valve
(OPEN 11 “VENT”)
. Check the other
valves remain closed
(6 “LIQUID “and 7 “AIR” closed).
o
Plug the equipment
to the 120 V/60 Hz supply line.
o
Activate the switch on the left (
Activate switch 1
) (
yellow arrow in the
figure
) which activates the fan.
o
Activate the switch on the right (
Activate switch 2
) (
green arrow in the
figure
) which activates the compressor.
Please, follow the correct order of activation of the switches.
o
Wait for 12 minutes
to remove the moisture of the pressure tank.
o
Deactivate the switch on the right (
deactivate switch 2
) (
green arrow in
the figure
) which deactivates the compressor.
o
Deactivate the switch on the left (
deactivate switch 1
)
(yellow arrow in
the figure
) which deactivates the fan.
Please, follow the correct order of activation of the switches.