Battery Replacement 

 

 

 

 

 

When the remaining battery charge indicator changes to            , the battery charge is 

low.  

When the battery voltage drops and reaches to the final voltage, “E-B” (refer to 

Battery 

Alarm

 on page 13) will be displayed on the LCD and the Gas Leak Detector will not be 

working. Replace the batteries. 

 

 

 

 

 

 

 
1)  Open the Velcro tape of the soft case and open the side zipper. 
2)  Open the battery lid of the back of the Gas Leak Detector and install two new 

batteries (size AA alkaline) as shown on the bottom of the compartment. 

3)  Close the battery lid firmly. 
4)  Zip the right and left of the soft case and close the Velcro tape. 

 

 

 

 

 

  Use the same kind of batteries. 

  Always replace two batteries at the same time. 

 

Due to the characteristics of the batteries, the battery life will be shorter 

when the surrounding temperature is lower than room temperature.

 

NOTE 

Battery lid 

Velcro tape 

  Make sure to use size AA LR6 alkaline dry cell batteries. 

NOTE 

 

- 14 - 

5. Replacement of Consumable Parts 

 

 

  

Filter Element Replacement 

 

When the Filter Element is dirty or wet, or when the water or liquid is inside the Drain 

Filter, clean out the Drain Filter and replace the Filter Element. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)  Turn the filter case counterclockwise and 

remove it. 

 

 

 

 

 

 

2)  Remove the O-ring from inside the cap. 

 

3)  Replace the Filter Element with a new filter. 

 

 

 

 

 

 

 

 

 

 

 

 

4)  Attach the O-ring, put the filter case back 

together and reassemble. 

 

 Do not replace the Filter Element while the Gas Leak Detector is 

operating.

 

Dust or other foreign matter may enter the Gas Leak 

Detector. 

  Mount the Filter Element correctly. If the Filter is not in place properly, it 

will not function properly and will not be able to detect correctly. 

  Attach the filter case securely.

 

If the filter case is loose, water or other 

foreign matter may leak into the Gas Leak Detector. 

  If water or liquid reaches inside the Gas Leak Detector through the Filter 

Element, it is in need of repair.

 

It will not be able to detect correctly. 

CAUTION

 

Do not push or poke the Filter Element. It may damage the waterproof structure. 

NOTE 

O-ring

FE-2  

Filter Element

Filter Case

Cap

Drain Filter 

If water, dust, or other foreign 

matter is in the Drain Filter, be 

careful not to enter into the Gas 

Leak Detector. 

CAUTION

 

Clean the inside of the cap and filter 

case with a dry cloth as needed.

 

R

emove water or liquid completely and 

dry the parts before replacing with a 

new Filter Element. 

NOTE 

Make sure to attach FE-2 Filter 

Element between the Cap and 

Filter Case. 

CAUTION

 

Содержание XP-703D III

Страница 1: ...tector This instruction manual explains the use of three models listed on the left Keep this Instruction Manual available for quick reference when needed Read this Instruction Manual and thoroughly un...

Страница 2: ...ilent Mode No Operation Sound 11 Deactivating the Alarm Buzzer 12 Lighting the Backlight 12 4 Error Displays 13 5 Replacement of Consumable Parts 14 Filter Element Replacement 14 Battery Replacement 1...

Страница 3: ...in preparing the Gas Leak Detector However if any items are missing or damaged please contact your New Cosmos distributor Replacements for any missing or damaged items will be sent Name Quantity Gas...

Страница 4: ...stand thoroughly this Instruction Manual regardless of your experience with using Gas Leak Detectors Do not use this Gas Leak Detector for improper purpose Do not use this Gas Leak Detector in undocum...

Страница 5: ...the batteries are leaking when the remaining battery charge is low Do not disassemble alter or change the structure or electric circuits of the Gas Leak Detector It may affect its performance Do not l...

Страница 6: ...4 2 Part Names and Functions 1 2 10 6 8 4 3 9 7 5 11...

Страница 7: ...s light if the concentration is very high These lamps also flash when an error occurs in the pump or sensor 8 Buzzer hole The buzzer sounds 9 LCD Displays the gas sensitivity and messages a The remain...

Страница 8: ...6 No Name Functions 1 Side Zipper Open the zipper to replace the batteries 2 Back Pocket The Operating Guide is stored here 3 Inside Pocket A Replacement Filter Element is stored here Soft case 1 3 2...

Страница 9: ...d close the zippers both sides and Velcro tape The Gas Leak Detector is in the soft case from the shipment 2 Insert the Attachment to the Drain Filter The attachment is inserted to the drain filter fr...

Страница 10: ...p is completed the highest sensitivity level 4 lamp will flash The maximum warm up time is three minutes Always perform the daily check before use Refer to page 16 WARNING STEPS 3 Detection Turn OFF p...

Страница 11: ...as sensitivity lamp When the gas sensitivity level is decreased beyond 1 the level will return to level 4 Increasing the Gas Sensitivity Level Each time pressing the POWER SENSITIVITY button twice dou...

Страница 12: ...p sound for 3 seconds and then it will return to display the gas sensitivity level If Zero Adjustment is not able to be performed the buzzer sound will beep and it remains to display the gas sensitivi...

Страница 13: ...ncentration gas of any in the following table is detected leave the Gas Leak Detector in clean air for a certain period of time before turning OFF the power Turning OFF the power immediately may affec...

Страница 14: ...d ON OFF The alarm sound indicator on the LCD will light buzzer ON or go out buzzer OFF Lighting the Backlight The LCD backlight lights by pressing the ZERO RESTART PUMP BACKLIGHT button It also light...

Страница 15: ...g ON the power several times there may be a problem with the sensor Request repairs Pump Error Error lamps flash Water or liquid may have been sampled or the inlet may be blocked Remove the water or l...

Страница 16: ...function properly and will not be able to detect correctly Attach the filter case securely If the filter case is loose water or other foreign matter may leak into the Gas Leak Detector If water or li...

Страница 17: ...ipper 2 Open the battery lid of the back of the Gas Leak Detector and install two new batteries size AA alkaline as shown on the bottom of the compartment 3 Close the battery lid firmly 4 Zip the righ...

Страница 18: ...flash or the alarm buzzer will not sound contact your New Cosmos distributor Attachment Check the Attachment for any wear or damage which may affect operations If any replace with a new Attachment Fil...

Страница 19: ...lacement Parts and Options Part Name Model Part Code Remarks Filter Element 10pcs FE 2 59160022 Drain Filter DF 114 59070018 Inspection Gas EG 10D 59150300 Attachment AT 2B 20524489 For tubing and cou...

Страница 20: ...ll not turn ON by pressing the POWER SENSITIVITY button The battery polarity is reversed Insert the batteries correctly Battery Replacement on page 15 Battery exhaustion Replace the batteries Displayi...

Страница 21: ...After examination of allegedly defective product return to New Cosmos with freight prepaid should the product fail to conform to this warranty customer s only remedy and New Cosmos s only obligation...

Страница 22: ...ressure Range Atmospheric pressure 800 to 1100hPa Operating Temperature and Humidity Range 0 to 40 degrees C less than 85 RH with no condensation Dimensions Approx 38 W x 130 H x 32 D mm excluding pro...

Страница 23: ...of a metal oxide semiconductor that is sintered in a ball on a platinum wire coil that functions as both a heater and electrode It detects the change of electrical conductivity occurred by oxidation r...

Страница 24: ...naka Yodogawa ku Osaka 532 0036 Japan Tokyo Branch New Cosmos Electric Co Ltd 2 6 2 Hamamatsu cho Minato ku Tokyo 105 0013 Japan Phone 81 3 5403 2715 Fax 81 3 5403 2710 Email e info new cosmos co jp U...

Отзывы: