6 - INSTALLATION
6.14 - Wall mounting of the GS indoor unit
The indoor unit must be installed inside and mounted on a
wall with the water connections facing down.
The indoor unit must be installed in a dry and ventilated
compartment.
The indoor unit cannot be installed in a place with the
presence of volatile, corrosive or flammable liquids or
gases.
It is recommended to install the indoor unit close to the
net water system.
Sufficient space must be left around the indoor unit for
maintenance operations and to ensure good ventilation
(Figure 6-2).
The indoor unit must be mounted on a wall according to the
following instructions:
1.- Take the expansion plugs and mounting bracket from the
accessories. Place the mounting bracket on the wall in
the desired position making sure it is horizontal. Mark the
position of the screws on the wall through the holes on the
bracket;
2.- Drill the wall with holes of the correct diameter;
3.- Unscrew the screws from the expansion plug;
4.- Attach the mounting bracket to the expansion anchors
without overtightening;
5.- With a hammer insert the wall anchors. Use a wrench to
tighten the nuts to secure the mounting plate to the wall;
6.- Hang the indoor unit on the mounting plate. Make sure it
hangs well before leaving the unit. The wall installation is
completed.