INSTALLATION TYPES
This microwave oven is designed for adaptation to
the following three types of ventilation:
A. Outside Top Exhaust (Vertical Duct)
B. Outside Back Exhaust (Horizontal Duct)
C.Recirculating (Non-Vented Ductless)
OUTSIDE TOP EXHAUST
(VERTICAL DUCT)
OUTSIDE BACK EXHAUST
(HORIZONTAL DUCT)
RECIRCULATING
(NON-VENTED DUCTLESS)
Adaptor in Place for
Outside Top Exhaust
2
B
C
Adaptor Must Be
Moved to the Back for
Outside Back Exhaust
(Choose A, B or C)
Installation Instructions
NOTE:
Read the next two pages only if you plan to vent your
exhaust to the outside. If you plan to recirculate the air back
into the room, proceed to page 20.
Models are shipped for
recirculating exhaust.
Some models have a
disposable charcoal filter
installed to help remove
smoke and odors.
EQUIVALENT NUMBER
EQUIVALENT
DUCT PIECES
LENGTH
x
USED
=
LENGTH
Rectangular-to-Round
5 Ft. (1.5 m)
x
( )
=
Ft. or m
Transition Adaptor*
Wall Cap
40 Ft. (12.2 m)
x
( )
=
Ft. or m
90° Elbow
10 Ft. (3 m)
x
( )
=
Ft. or m
45° Elbow
5 Ft. (1.5 m)
x
( )
=
Ft. or m
90° Elbow
25 Ft. (7.6 m)
x
( )
=
Ft. or m
45° Elbow
5 Ft. (1.5 m)
x
( )
=
Ft. or m
Roof Cap
24 Ft. (7.3 m)
x
( )
=
Ft. or m
Straight Duct 6“ (15.2 cm)
1 Ft. (0.3 m)
x
( )
=
Ft. or m
Round or 3
1
⁄
4
“ x 10“
(8.2 x 25.4 cm Rectangular)
Total Ductwork
=
Ft. or m
Equivalent lengths of duct pieces are based on actual tests
and reflect requirements for good venting performance with
any vent hood.
* IMPORTANT:
If a rectangular-to-round transition
adaptor is used, the bottom corners of the damper
will have to be cut to fit, using the tin snips, in order
to allow free movement of the damper.
NOTE:
If you need to install ducts, note that the total
duct length of 3
1
⁄
4
”
x 10
”
(8.2 x 25.4 cm) rectangular or
”
(15.2 cm) diameter round duct
Outside ventilation requires an EXTERNAL EXHAUST
NOTE:
It is important that venting be installed using
the most direct route and with as few elbows as possible.
This ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
Exhaust connection:
The exhaust adaptor has been designed to mate with
a standard 3
1
⁄
4
”
x 10
”
(8.2 x 25.4 cm) rectangular duct.
If a round duct is required, a rectangular-to-round
Maximum duct length:
For satisfactory air movement, the total duct length of
3
1
⁄
4
”
x 10
”
(8.2 x 25.4 cm) rectangular or
6
”
(15.2 cm) diameter round duct should not
exceed 120 equivalent feet (36.5 m).
Elbows, transitions, wall and roof caps,
etc.,
present additional resistance to airflow and are
equivalent to a section of straight duct which is longer
than their actual physical size. When calculating the total
duct length, add the equivalent lengths of all transitions
and adaptors plus the length of all straight duct sections.
The chart below shows you how to calculate total
equivalent ductwork length using the approximate feet
of equivalent length of some typical ducts.
Installation Instructions
INSTALLATION INSTRUCTIONS FOR EXTERNAL EXHAUST DUCTING
DUCT.Read the following carefully.
(12.
5”
should not exceed 120 equivalent feet (36.5 m).
diameter/ 6
(12.
5”
diameter/
7 cm)
7 cm)
transition adaptor must be used.
diameter duct is acceptable to use.
"
A 5"""''''' " (12.7cm)/ 6" (15.2cm)
"
NOTE: This microwave is shipped assembled for Recirculating.
Select the type of ventilation required for your installation and
proceed to that section.
See page 12
See page 17
See page 21