INSTALLATION TYPES

This microwave oven is designed for adaptation to

the following three types of ventilation:

A. Outside Top Exhaust (Vertical Duct)

B. Outside Back Exhaust (Horizontal Duct)
C.Recirculating (Non-Vented Ductless)

OUTSIDE TOP EXHAUST
(VERTICAL DUCT)

OUTSIDE BACK EXHAUST
(HORIZONTAL DUCT)

RECIRCULATING
(NON-VENTED DUCTLESS)

Adaptor in Place for

Outside Top Exhaust

2

B

C

Adaptor Must Be

Moved to the Back for

Outside Back Exhaust

(Choose A, B or C)

Installation Instructions

NOTE:

 Read the next two pages only if you plan to vent your

exhaust to the outside. If you plan to recirculate the air back

into the room, proceed to page 20.

Models are shipped for
recirculating exhaust.
Some models have a 
disposable charcoal filter 
installed to help remove
smoke and odors.

EQUIVALENT NUMBER

EQUIVALENT

DUCT PIECES

LENGTH 

x

USED

=

LENGTH

Rectangular-to-Round

5 Ft. (1.5 m)

x

(    )

=

Ft. or m

Transition Adaptor*

Wall Cap

40 Ft. (12.2 m)

x

(    )

=

Ft. or m

90° Elbow

10 Ft. (3 m)

x

(    )

=

Ft. or m

45° Elbow

5 Ft. (1.5 m)

x

(    )

=

Ft. or m

90° Elbow

25 Ft. (7.6 m)

x

(    )

=

Ft. or m

45° Elbow

5 Ft. (1.5 m)

x

(    )

=

Ft. or m

Roof Cap

24 Ft. (7.3 m)

x

(    )

=

Ft. or m

Straight Duct 6“ (15.2 cm) 

1 Ft. (0.3 m)

x

(    )

=

Ft. or m

Round or 3

1

4

“ x 10“

(8.2 x 25.4 cm Rectangular)

Total Ductwork

=

Ft. or m

Equivalent lengths of duct pieces are based on actual tests 
and reflect requirements for good venting performance with 
any vent hood.

* IMPORTANT: 

If a rectangular-to-round transition

adaptor is used, the bottom corners of the damper
will have to be cut to fit, using the tin snips, in order
to allow free movement of the damper.

NOTE:

If you need to install ducts, note that the total

duct length of 3

1

4

x 10

(8.2 x 25.4 cm) rectangular or

(15.2 cm) diameter round duct

Outside ventilation requires an EXTERNAL EXHAUST 

NOTE:

It is important that venting be installed using 

the most direct route and with as few elbows as possible. 
This ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.

Exhaust connection: 

The exhaust adaptor has been designed to mate with 
a standard 3

1

4

x 10

(8.2 x 25.4 cm) rectangular duct.

If a round duct is required, a rectangular-to-round 

Maximum duct length: 

For satisfactory air movement, the total duct length of 
3

1

4

x 10

(8.2 x 25.4 cm) rectangular or
 6

(15.2 cm) diameter round duct should not 

 exceed 120 equivalent feet (36.5 m). 

Elbows, transitions, wall and roof caps,
etc.,

present additional resistance to airflow and are

equivalent to a section of straight duct which is longer
than their actual physical size. When calculating the total
duct length, add the equivalent lengths of all transitions
and adaptors plus the length of all straight duct sections.
The chart below shows you how to calculate total
equivalent ductwork length using the approximate feet
of equivalent length of some typical ducts.

Installation Instructions

INSTALLATION INSTRUCTIONS FOR EXTERNAL EXHAUST DUCTING

DUCT.Read the following carefully.

(12.

5”

should not exceed 120 equivalent feet (36.5 m).

diameter/ 6

(12.

5”

diameter/ 

7 cm)

7 cm)

transition adaptor must be used. 
diameter duct is acceptable to use. 

"

  A 5"""''''' " (12.7cm)/ 6"  (15.2cm) 

"

NOTE: This microwave is shipped assembled for Recirculating.
Select the type of ventilation required for your installation and
proceed to that section.

See page 12

See page 17

See page 21

Содержание COS-3019ORM2SS

Страница 1: ...SAFETY INSTRUCTIONS Carefully read the following Important information regarding installation safety and maintenance Keep these instruction for future reference COS 3019ORM2SS INSTALL GUIDE INSPIRING...

Страница 2: ...0Hz 1550W 1000W 53L 1 9 cu ft 345mm 13 6 29 8 x 16 4 x 15 4 Specifications Before You Use Your Microwave CONTENTS General information Important Safety Instructions 3 Electrical Requirements 3 Damage S...

Страница 3: ...ER ANY CIRCUMSTANCES CUT DEFORM OR REMOVE ANY OF THE PRONGS FROM THE POWER CORD DO NOT USE WITH AN EXTENSION CORD IMPORTANT SAFETY INSTRUCTIONS Ensure proper ground exists before use ELECTRICAL REQUIR...

Страница 4: ...MUST BE CONNECTED TO AT LEAST ONE WALL STUD 1 Fold back all 4 carton flaps fully against carton sides Then carefully roll the oven and carton over onto the top side The oven should be resting in the...

Страница 5: ...is level If the cabinets have a front overhang only with no back or side frame install the mounting plate down the same distance as the front overhang depth This will keep the microwave level Measure...

Страница 6: ...need to install ducts note that the total duct length of 31 4 x 10 8 2 x 25 4 cm rectangular or 15 2 cm diameter round duct Outside ventilation requires an EXTERNAL EXHAUST NOTE It is important that v...

Страница 7: ...od venting performance with any vent hood Total Length 63 Ft 19 1 m EXTERNAL EXHAUST DUCTING Installation Instructions OUTSIDE TOP EXHAUST A Vertical Duct INSTALLATION OVERVIEW A1 Attach Mounting Plat...

Страница 8: ...nt hangs below the cabinet bottom shelf IMPORTANT If filler blocks are not used case damage may occur from overtightening screws Insert a self aligning screw through top center cabinet hole Temporaril...

Страница 9: ...8 Extend the house duct down to connect to the exhaust adapter Seal exhaust duct joints using furnace duct tape for high temperature applications B OUTSIDE BACK EXHAUST Horizontal Duct INSTALLATION O...

Страница 10: ...cord to fit through Back of Microwave Roll the blower unit 90 Back of Microwave 3 Before Rotation After Rotation Attach the exhaust adaptor to the rear of the oven by sliding it into the guides at the...

Страница 11: ...the wires are not pinched C1 Attach the plate to the wall using toggle bolts At least one wood screw must be used to attach the plate to a wall stud Remove the toggle wings from the bolts Insert the b...

Страница 12: ...that the blower plate is cor rectly installed on the unit C Recirculating Non Vented Ductless C Recirculating Non Vented Ductless C4 FOR EASIER INSTALLATION AND PERSONAL SAFETY WE RECOMMEND THAT TWO...

Страница 13: ...n has been installed according to instructions 1 BEFORE YOU USE YOUR MICROWAVE Ensure proper ground exists before use INSTALLATION INSTRUCTIONS 3 ring and glass tray in cavity Install turntable 4 KEEP...

Страница 14: ...receptacle 5 Read operating instructions before testing the product 6 Turn on the exhaust fan at Turbo speed and confirm it is operating by using a tissue it will stick to the filter 7 Confirm the ou...

Страница 15: ...ot Return This Product To The Store If you have a problem with this product please contact Cosmo Customer Support at 1 888 784 3108 DATED PROOF OF PURCHASE MODEL AND SERIAL REQUIRED FOR WARRANTY SERVI...

Страница 16: ...n of this manual is available at www cosmoappliances com Cosmo is constantly making efforts to improve the quality and performance of our products so we may make changes to our appliances without upda...

Отзывы: