Fig.9.3
Convection cooling
m
easurement
result
※Measurement results with TUNS1200F28
■
Here is an example of forced air cooling with heatsink.
■
Please consider this example as a design guideline because it changes by the heat
dissipation environment. Please measure the temperature of the actual equipment
eventually.
■
If it is difficult to measure the center of the baseplate, please measure the leeward
side of the baseplate edge.
Fig.9.4
Forced air cooling
Heat sink example
Fig.9.5
Environment
A-24
9.3 Examples of Forced air cooling
Applications Manual
TUNS1200
0
200
400
600
800
1000
1200
1400
0
20
40
60
80
100
Ou
tp
u
t
p
o
we
r
[W]
Ambient temperature [
℃
]
100VAC
200VAC
277VAC
150
×
95
×
50mm
(
EK95 L150 MIZUTANI ELECTRIC IND.CO.,LTD
)
Thermal resistance
:
1.1
℃
/W (at Convection cooling
)
AIR
Anemometer
800
FAN
470
×
Wind tunnel
Heatsink
Silicone grease
(Momentive
YG6260)
External components
TUNS1200F
Printed Board
(FR-4 t=1.6mm)
20
[mm]
Ambient temperature
measurement point
60